Search results

  1. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    OK, MikefromLondon, here is my attempt to draw your proposed solution (with optional capacitor shown for completeness). Have I got this right? BTW, I find AutoCAD LT very useful for this sort of thing. As they say, a picture is worth a thousand words...
  2. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    Actually, I thought it was impossible to wire the pushbutton with just two wires. The attached diagram shows how I had assumed it needed to be done. This version ensures that the LED stays lit at all times.
  3. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    I am a bit puzzled by that question. I have never seen a bell button that was not a push to activate and release to deactivate, i.e. non-latching, and have no reason to believe that I have just bought anything different. Surely no one would want any possibility of a bell being left to sound...
  4. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    My bell transformer is as shown below. The specs state clearly that the nominal output is 8v AC. I have also confirmed with my ancient multimeter that there is no significant DC output. The no-load output is still 16v AC. However, our mains voltage is at the legal maximum of 254.4v (240v + 6%)...
  5. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    It does indeed simply say 12V. The supplier's rather limited installation instructions also state "The voltage range for the LED is based between 8 and 12 volt. You can use either continuous or alternating current. Both are possible". Elsewhere in those instructions it says "You will need a...
  6. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    Let me also correct a misunderstanding by ericmark. Finding a 12 volt DC LED power supply is not my problem. I have already identified the following item as appearing to be an exact match for my needs. However, I don't wish to introduce added cost and installation complications if they are not...
  7. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    Many thanks for all the rapid and useful responses so far. I have attached a couple of photos that show the sort of illuminated pushbutton I am talking about. The circular LED-powered light is white. I'm not sure if there is any way to dismantle it and replace a blown LED, so I am not planning...
  8. H

    Is it safe to run 12v DC LED from 8v AC bell transformer?

    I have bought a rather classy and expensive engraved stainless steel bell push fitted with a Bulgin-style pushbutton that has an integral LED rated at 12v DC. I would want the LED to be lit at all times (except perhaps while pressing the pushbutton). It has been difficult to get much...
Back