Search results

  1. Untitled

    Untitled

  2. Untitled

    Untitled

  3. Untitled

    Untitled

  4. Flashing at porch ridge

    Flashing at porch ridge

  5. M

    CORSA 1.2 MILOMETER READING 15NP WHAT DOES THIS MEAN

    :lol: :lol: :lol: :lol: Love it breezer
  6. M

    Escort van - Whats this called?

    Thanks for the replies alford and ^neo^ I bought a plug from a local Ford dealer yesterday for the bargain price of 66p including VAT :lol: I fitted it and have had the van out today and all is ok Started 1st time on several occasions I checked the other pipes and there are no leaks but I...
  7. M

    Escort van - Whats this called?

    I have a 1994 L reg Ford Escort 1.8 diesel van. Recently, I have been having some trouble starting it. It cranks for around 15 to 20 seconds then catches and the engine starts ok but over the last week, it cranks but now it will not start. It won't start off a jump so tonight a mate of...
  8. Untitled

    Untitled

  9. Untitled

    Untitled

  10. Untitled

    Untitled

  11. Untitled

    Untitled

  12. Untitled

    Untitled

  13. Escort van diesel leak

    Escort van diesel leak

  14. M

    Only one hot radiator the rest are all cold?

    I had this ages ago following draining down and refilling the c/h system. I seem to remember on mine the flow pipe was roasting hot but the return pipe was stone cold and only the rad in the same room as the boiler would heat up. Assuming its a combi, there should be an air vent either on...
  15. M

    Hot water problem with Chaffoteaux et Maury Sterling PP

    I drained the sludge remover out of the c/h system yesterday and it was pretty dirty. I refilled the system back up and drained it down a couple of times and then filled it up to about 1.2 bar, drained down again but this time turned the filling loop on and flushed the system out whilst...
  16. M

    Hot water problem with Chaffoteaux et Maury Sterling PP

    I would really appreciate any responses to the above, as I want to try and get things sorted out over this weekend. Many thanks in advance. Mr M
  17. M

    Hot water problem with Chaffoteaux et Maury Sterling PP

    Sorry couldn't answer fully before, I was just dashing out, so..... I left the hot water running for about 10 minutes and the flow pipe (when felt close to the boiler) remains stone cold so it does appear as though the diaphragm is not passing I take it that a "combination" fault is not...
  18. M

    Hot water problem with Chaffoteaux et Maury Sterling PP

    Thanks Tony, Do I need to remove the secondary heat exchanger to clean it or will the sludge remover which I currently have running through the c/h system do this job for me? If I need to remove it, is there anything which you would recommend for cleaning it and following removal, what's...
  19. M

    Hot water problem with Chaffoteaux et Maury Sterling PP

    Thanks ChrisR, 1) I did reduce the flow rate from the hot water tap (not sure to what litres/minute though) by slightly turning the ballofix until the flow from the tap reduced but the burner flame does exactly the same and the water temp is also the same 2) If it is this, am I wasting my...
  20. M

    Hot water problem with Chaffoteaux et Maury Sterling PP

    Hello, I have a Chaffoteaux et Maury Sterling PP combi boiler. The central heating is working as it should but the hot water temperature is not as hot as it should be. When the hot tap is turned on, after a few seconds, hot water starts to come through but then the temperature drops to luke...
Back
Top