  1. S

    creda 3.4kw stroage heater circa 1984-87

    can someone advise me what the likely cause is when my storage heater comes on warms up but within hours blows the thermal link and what part I am likely going to have to replace to resolve this. Until recently worked very well
  2. S

    electric shower problem

    The following problem is occuring with my 8.5kw electric shower. When the 45amp pullcord control switch is switched on the the neon light on it illuminates, when the on/off switch on the shower is turned on the neon light on the 45amp control switch goes out and the shower fails to produce...
  3. S

    Bath and basin waste problem

    In my bathroom I have had over the years continual problems with water backflowing up through the bath sink when draining the basin as well as the bath taking long periods to drain. Yes it has not been helped on occasions when slight blockages occur but I feel that its never been quite right at...
  4. S

    kitchen cabinet Masonry fixings

    would you care to elaborate
  5. S

    kitchen cabinet Masonry fixings

    Only problem I foresee is that the inner leaf of the wall cavity construction is wimpey no fines which I feel may make it difficult to get a fixing with any of these methods, any other suggestions.
  6. S

    kitchen cabinet Masonry fixings

    thanks i will go for that
  7. S

    kitchen cabinet Masonry fixings

    I am fitting wall cabinets in a masonry wall (brick coated with 10mm or so of plaster). Can anyone advise me what would be the most suitable fixings
  8. S

    cooker cable connection

    Hi, When connecting cooker cable to the cooker which I have done many times the wires terminate between two plates secured by a nut, my problem is I have mislaid the plates I describe. Can anyone advise me were I may get replacements and what they are called (Very annoying)
  9. S

    Preparation for laying new turf

    Thank you for your comments and the useful link, the point I am making is would you expect good results if you lay turf directly onto nothing more than 4inches of building sand containing little or no soil, I am guessing not any research I have done refers mainly to laying on soil and certainly...
  10. S

    Preparation for laying new turf

    I would say it is more fine than I would expect to find in my garden. As far as depth of top soil goes there are areas of the intended lawn that are nothing but sand about 3-4inches deep and none of it pure soil but rather a mixture which is more sand than soil. I will try to include some photos
  11. S

    Preparation for laying new turf

    I have brought in a local firm who advertise as turfing specialists amongst other things, however I am concerned with the preparation for the turf and I would like some advise. The turf is being laid on part of an existing driveway we lifted the blocks that were on an area about 60m2, the...
  12. S

    earth bonding kitchen pipes

    when carrying out earth bonding to copper pipes under the kitchen sink would bonding back to the earth connection in a close socket be sufficient?
  13. S

    Painting Ceramic tiles

    Is it necessary to use tile paint for this job or would gloss paint do just as well, not as many available colours in the tile paint. Or is there any other alternative paint.
  14. S

    1.5mm cable for sockets?

    The method that has been used is free air I suppose, it runs down the back of kitchen units then approx 3metres along the floor and into a double socket. I could likely replace it without too much trouble. It is the supply for a washing machine and fridge.
  15. S

    1.5mm cable for sockets?

    Is it under any circumstances acceptable to use 1.5mm twin and earth cable to run an additional socket from an existing socket or is this cable only suitable for lighting circuits.
  16. S

    Connecting Panel Heater

    Have got a new panel heater here, first thing I notice is it only has a 2 wire cable with no earth, is this completely abnormal.? "The installation must be equipped with an all pole diconnection mechanism with break contact distance of at least 3mm in each pole", what am I looking for in...
  17. S

    Bathroom basin waste fittings

    the pipe is plastic
  18. S

    Bathroom basin waste fittings

    I have a flat built in the late 60s early 70s and I intend to renew the basin which is an original fitting as I presume the waste is. My question is regarding the size of the fitting for the waste which is neither 32mm or 38mm but rather something in between. Thing is I need to make an...
  19. S

    Fuses/Breakers

    Is this set up in my CU okay.. 5 amp light circuit 15 amp for storage heaters 15 amp for water immerser 30 amp for Ring Mains 30 amp for cooker
  20. S

    Basic Stuff Plumbing waste fittings

    I understand that there are several choices for sink and bathroom basin waste fittings, can anyone advise me of the benefits relating to 1 1/2, 1 1/4 and McAlpine. Are there other size options, my quess is that its just the bigger the pipe the faster the waste drains. What are the benefits of a...