  1. Risteard

    EICR Faults

    I'm sorry, but you're wrong. Knowing about previous findings IN ADVANCE can allow for more thorough and targeted inspection of potentially concerning parts of the installation. Reading the previous Report after the fact prevents this.
  2. Risteard

    EICR Faults

    Indeed. It demonstrates fundamental stupidity and should require brutal reeducation with a wooden spoon and Chinese water torture. The date of installation is not relevant (aside from age of cables and accessories etc.)
  3. Risteard

    Pull cord reposition

    Indeed. Pure water is an insulator.
  4. Risteard

    Double socket power help.

    Square pins are an inferior design all round. (Excuse the pun.)
  5. Risteard

    EICR Faults

    Indeed. It's difficult to quanitfy deterioration without any previous data. (Or even get an idea whether any remedial work was carried out to address previously identified issues, or whether additions or alterations have been made.) Sadly in the majority of cases previous certificates and/or...
  6. Risteard

    EICR Faults

    Pervious reports should always be supplied and reviewed where they are available.
  7. Risteard

    OK to have insulated inner cores within plastic trunking?

    No, it isn't the same at all. Otherwise there would be no reason for the two designations.
  8. Risteard

    OK to have insulated inner cores within plastic trunking?

    IPXXD is far less stringent than IP4X.
  9. Risteard

    EICR Faults

    Nonsense.
  10. Risteard

    EICR Faults

    Hence why I stated "if it is problematic". However if it is outside of the DNO's design criteria (even if Zs is tolerable throughout) then there may be an issue which needs rectifying, e.g. a poor joint. So it cannot simply be ignored - although it will be for the DNO to determine whether it's...
  11. Risteard

    EICR Faults

    Untrue. There is no need to have a rental property wholly compliant with present day Regulations. And whilst Ze is a supply-side issue it still needs to be rectified if it's problematic. Obviously this would be achieved by reporting it to the DNO. I thought that would be obvious.
  12. Risteard

    Pull cord reposition

    A stupid suggestion though. It is also likely to fray the cord due to friction.
  13. Risteard

    Those extension leads, on a drum

    Quite often used in domestic environments here.
  14. Risteard

    Maybe a silly question but - Does my board have an RCA Breaker..

    Presumably he means Type A RCD protection.
  15. Risteard

    Those extension leads, on a drum

    They're frequently used indoors.
  16. Risteard

    Those extension leads, on a drum

    It's actually called in-service inspection and testing of electrical equipment.
  17. Risteard

    Those extension leads, on a drum

    I'm not a fan of trip hazards. I advocate sufficient socket-outlets so that extension leads aren't required.
  18. Risteard

    Add light switch to garage

    I was wondering how everyone else missed this very obvious implication.
  19. Risteard

    Those extension leads, on a drum

    It doesn't need to be anywhere close to its (not "it is") maximum capacity to need to be fully unwound. The coiled capacity is greatly reduced. And it can heat up very quickly. Don't expect me to promote irresponsibility.
  20. Risteard

    Those extension leads, on a drum

    Yes. It's good practice always to fully unwind the lead.