  1. Risteard

    Poss To Add Radial Circuit To Fuse Box?

    Fuses can't trip! They rupture.
  2. Risteard

    Outside wall light with built-in camera

    ESP GuardCam Deco.
  3. Risteard

    frizzled Line socket - why is it always L?

    It's not always the line, but a logical explanation would of course be a loose connection between the fuse and carrier.
  4. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    No need to apologise. I've done jobs in Sligo before, but like you I agree it's too far for most things. About a two hour drive to Sligo Town from here.
  5. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    It would hardly align with their obligations in respect of IEC/CENELEC either, so couldn't actually be done anyway.
  6. Risteard

    Measuring Zs with all circuits connected or just the circuit being tested.

    Now you'll be able to perform a proper manly loop impedance test where no RCDs are present.
  7. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    I'm just looking out for you. I like you too much Andy From Sligo to see you doing hard labour.
  8. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    Better than spending a few years in gaol. (Or even longer in the graveyard.)
  9. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    It also can't be PVC insulation, bedding or sheath.
  10. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    Indeed. Better yet, he could get his Electrician to source the proper cable.
  11. Risteard

    Measuring Zs with all circuits connected or just the circuit being tested.

    You may be surprised to learn that they claim nowhere near the measurement accuracy which many seem to assume. They are more indicative.
  12. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    Perhaps it's not Electricians that it's intended to protect.
  13. Risteard

    Measuring Zs with all circuits connected or just the circuit being tested.

    It doesn't, because even the instrument manufacturers will state unequivocally that high current loop testing is the preferred means where possible.
  14. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    Clearly it's a safety requirement, irrespective of individual views of the need for or wisdom of the Rule.
  15. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    Brown & Earth from the luminaire. Twin brown between switches. Single brown from last switch to luminaire switched phase connection. Other methods are of course possible.
  16. Risteard

    Measuring Zs with all circuits connected or just the circuit being tested.

    Well then I would dispute their logic. I wouldn't even entertain a low trip setting on non-RCD protected wiring.
  17. Risteard

    Measuring Zs with all circuits connected or just the circuit being tested.

    No. Logic tells us that 2 wire high current testing is always the better measurement to utilise. Low current loop testing is simply a compromise due to the use of residual current devices.
  18. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    The conversion method isn't common here. Conventional two-way (and intermediate) switching is generally employed.
  19. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    No. The fan would require a neutral. You could use twin brown with an insulated and sheathed single blue, but that would be less logical than a brown & blue with insulated and sheathed single brown.
  20. Risteard

    can you use 3 phase SWA cable for 230vAC single phase?

    One option is a T&E alongside an insulated and sheathed single brown. (I won't use the term "PVC/PVC" as PVC cables are actually prohibited for the past few years. The minimum cable requirement is Dca, -s2, d2, a2.) For smoke/CO detectors we actually have a specialist cable now called "RD415".