  1. S

    Never rains... Leak on lead joint!

    A lot of my customers are the same its easy to try but easier to f*** up :lol:
  2. S

    Never rains... Leak on lead joint!

    You can file it yes, cut it straight as possible then use a file I know its easy but I am a plumber.
  3. S

    Never rains... Leak on lead joint!

    Never think of replies like that. I always assume people know but yes you are right Red
  4. S

    Never rains... Leak on lead joint!

    Sounds like he doesn't want the job, sounds awkward doesn't carry kit for lead ????? Ok your answer as long as you have enough of the lead below the soldered bulb showing and having nice bit of lead you can use a leadlock on you should be able to manage it ( just like a compression fitting )...
  5. S

    Garden tap attached to heating pipe?

    Now you are talking sense
  6. S

    Garden tap attached to heating pipe?

    :lol: :lol: make sure you put plenty of inhibitor onto your garden too to keep the rust off the grass
  7. S

    Fitting New Mains Stopcock

    15mm is the same size as 1/2" imperial
  8. S

    Fitting New Mains Stopcock

    You will be ok because 15mm is the same as 1/2" I take it, it is copper coming in?
  9. S

    Lost pressure on shower

    But still check the shower filters first
  10. S

    Lost pressure on shower

    Ok you maybe right but never had the reason to use one so never relly looked till now. I have made them up using female Iron to copper then used a vent into the 1/2"
  11. S

    Lost pressure on shower

    http://www.screwfix.com/prods/19155/Plumbing/End-Feed-Fittings/Air-Vent-Cap-End-Feed-15mm But if you cannot solder you will have problems, I don't know about any plastic vents or compression.
  12. S

    Lost pressure on shower

    On the manufacturers instructions it will say that if you are rising to the loft and then back down to the shower you will need airvents on the highest part of the installation on the pipes to dispell any air that can get trapped even tho its pumped.
  13. S

    Lost pressure on shower

    Ok so its tank fed mains are there any filters on the inlet pipes to the pump or shower mixer? And I take it the pipes rise from the airing cupboard (just a guess) then back down to the shower? Are there any air vents in the loft?
  14. S

    Lost pressure on shower

    Mains cold water mixed with gravity fed hot water????????
  15. S

    radiators not getting warm

    It maybe air but you have said you have put isolating valves on these could well be restricting the flow and return to the radiators.
  16. S

    radiators not getting warm

    They get warm when the others are turned off may mean that they have been bled?
  17. S

    Vokera Linea-- loss of pressure.

    Pressue relief valve needs changing
  18. S

    Moving a boiler from one side of kitchen to other

    Leaving the fanlight open What a considerate Builder
  19. S

    Standpipe Height

    For the waste system You could if the sink is close enough get a combined washing machine/ sink trap and run the waste to that. As for the gas supply it still seems to be undersized. Usually the last metre can be run in 15mm, should be 22 off the meter.