  1. Abcplumb

    biasi riva advance he hot water issue

    Hi I think you should have called Biasi in the 1st place. Even tho they may have told you, that they wont cover it as its a system installation fault, but worth a try. How is the central heating? Does this cut off, or does the boiler make any knocking sound when on heating mode? If your...
  2. Abcplumb

    glow worm 30ci problems

    As you have said "gets to temp" once the boiler has reached its set temperature then it's suppose to cut out, other wise it can over heat, and radiators would be getting too hot. I think your boiler is fine. If any of my information has help you, please click the thanks tab on the right.
  3. Abcplumb

    Thermostat programmer off, CH still switching on and off

    The diverter valve function is to "divert" the heated water to the hot water or the heating, if this is faulty then the heated water would be passing into the central heating when it should be fully passing in the hot water. Its a very common fault on these boilers, it does suggest the system...
  4. Abcplumb

    Thermostat programmer off, CH still switching on and off

    Hi Any large amount of hot water usage will confirm the diverter valve fault. Washing machine is not a good one, as some machines heating the incoming cold water, so there is no hot water used by the washing machine, same for the dish washer. The best way to confirm would be early morning...
  5. Abcplumb

    Thermostat programmer off, CH still switching on and off

    Hi If you are certain that the heating is not coming on when you are using the shower, then we can look at other possibilities. You have to be 100% sure otherwise we'll be going round in circles. If your heating is not coming on when someone is using the showers then you know your...
  6. Abcplumb

    glow worm 30ci problems

    ooohhh Sorry :oops: Will not happen again
  7. Abcplumb

    glow worm 30ci problems

    Hi It does sound like the boiler is working fine, sometimes these things can play on your mind. If you do need and help in the future, visti our site. abcplumbingltd.co.uk
  8. Abcplumb

    glow worm 30ci problems

    Hi You need to check the setting of the heating dial. A certain setting means a set temperature. Try setting the heating setting to max, and check to see how long it takes before it cuts out. When it does cut out, check the radiator temperature. How is your hot water, and issues there?
  9. Abcplumb

    Thermostat programmer off, CH still switching on and off

    Hi Wireless devices can lose pairing, specially room states. I am not familiar with the one you have, but there could be a display which should state if it has lost pairing with the unit at the boiler. Its best to read the manual for your device. If you don't have it, you should be able to...
  10. Abcplumb

    glow worm 30ci problems

    Hi F1 indicates a ignition detection fault, which can be caused by the gas valve. A faulty solenoid is a common fault, but I would advice you to get it inspected by a Gas Safe engineer. You can hint him in the right direction :P Regards to your heating, the boiler is suppose to modulate...
  11. Abcplumb

    VOKERA 28 - WATER PRESSURE QUERY...

    Rusty There are a few things wrong here! :( Check if your filling loop is not left in a ON position. The filling loop is what is used to fill the boiler with water pressure. When you said the gauge is near the 3, does this happen when the heating is on? Also does the needle go down...
  12. Abcplumb

    Thermostat programmer off, CH still switching on and off

    Hi You have a programmable wireless room state, if I'm right. Sometimes these devices can lose pairing. You need to check this, once this is confirmed look at the boiler when you are NOT calling for heat. What does the display say? Also confirm the model number of the boiler. Try to...