  1. S

    Hot water upstairs 18degrees lower than downstairs

    I would still say that its going around a shower What shower do you have so that I can tell if it has built in NRVs That is the most likely fault Sherbert
  2. S

    Worcester Bosch Greenstar i 15 System Boiler Any Good ????

    sounds like the wrong size boiler to me Try the 24 or 30 Sherbert
  3. S

    Uponor underfloor heating installation

    Spot on me thinks Its not a manifold with pump etc Its just a thermostatic valve that restricts the flow of water through the coil on the return so that the heatloss through the pipes maintains an average temp on the small area Not the best idea as you cant turn on earlier than the main...
  4. S

    Help !!!!!! no registration

    Pray!! Let me guess ... he was cheap Get about one phone call a month with people asking us to sign off work ... tell them to contact building control Sorry but i have no sympathy Sherbert
  5. S

    Newly installed combi boiler causing pipe leaks

    Have had a similiar problem in that it only started after we put heat onto the systemThe original boiler was only 15Kw and the new combi was 30Kw not sure if it was due to the expansion being alot quicker on the pipes or pre-existing leak but only dropping every day luckily we had expressed...
  6. S

    Replacement combi...

    You dont have to have the boiler serviced by the installer ... it just has to be serviced yearly so that the warranty remains valid i will say that most boiler manufactures are top rate at getting boilers back up and running when under warranty and I have found Worcester and Baxi the top two...
  7. S

    Replacement combi...

    As a company I point blank refuse to break down labour and materials If we supply and fit the boiler then we remain responsibile for it under the warranty period .... as a WAI for worcester that is 5 years but as other posts have said it must be serviced every year and I think that applys to...
  8. S

    magnaclean filter and low loss header

    Yes .... That would be fine Also consider fitting the dual magnaclean that has a stariner built into it as well
  9. S

    Insufficient power to heat room with UFH

    Can you turn the temp of the Water going through the UFH .... look at the manifold .. also did you have underlay fitted and if so was it suitable for UFH ... it could be acting like a coat and stopping the heat from coming out
  10. S

    Hot water upstairs 18degrees lower than downstairs

    IF possible fit some non return valves on the pipework to the shower .. sounds like the cold is going around around the shower valve
  11. S

    it is ILLEGAL to sign off work from non-corgi

    can never get my head around why any CORGI registered installer will sign off work... If nobody signs it off then they cant get the work unless the public are prepared to accept it not being registered.... When will installers realise that by saying NO then in time this work will come our...