  1. yerino

    Opinon / Advice wanted on Install

    1) The condensing pipe is fine to go into the rainwater stack. .. However, they could of put an elbow as it came out the wall if they really wished, it would of just meant coring through the wall with a slightly bigger core bit than the elbow (then the elbow can push inside the wall neatly!)...
  2. yerino

    Swan neck mixer tap, weeping at base of neck

    A picture of the tap would help, then we could answer your question.
  3. yerino

    Loss of water pressure to washing machine ??

    How is your hot water pressure in all your other taps in your property?
  4. yerino

    Will CH pressure drop if no inhibitor has been added?

    Has it dropped 1 bar more than once? .. If so theres a leak!
  5. yerino

    Mixer tap

    With great care and using a ceramic drill bit.
  6. yerino

    Combi-boiler & Mixer Tap Shower

    Both hot and cold pressures are the same so the answer is no you shouldn't have a problem. :lol:
  7. yerino

    Drained Tank in attic, refilled, now no water

    Have you got a mixer tap (anywhere in the house)? If so, you could open up your hot tap and put your hand over the spout and slowly open up the cold tap (keeping your hand tight over the spout) and let the cold mains backfill up the hot and therefore hopefully clearing any air/blockages.
  8. yerino

    Power Flushing CH and Boiler

    Aha, didn't read the OP post well enough! :oops: .. Seco, it only needs to be temporarily 'sealed' so your "comment" makes no sense.
  9. yerino

    Power Flushing CH and Boiler

    Personally, I use a Sentinal Jetflush Powerflushing machine. With a litre of X800 chucked in and 6-8 hours of "flushing" the system is as good as new. Depends on the circumstances, if I'm putting in a new combi (sealed) system before I install the boiler, I use the flow and return pipes to...
  10. yerino

    Best types of wastes

    Clicker or coin :D
  11. yerino

    Problem Hot water flow rate bathroom

    Faulty/partially blocked check valve. Why not?
  12. yerino

    Power Flushing CH and Boiler

    You have to make it a sealed system. That means capping off the vent pipe to your F+E tank and cutting in a valve on the cold feed (to your rads) coming from the bottom of the F+E tank and turning it off! So there are no open ends (and no chance of backfilling the tank). My advice would...
  13. yerino

    Problem Hot water flow rate bathroom

    I don't think the problem is to do with any isolating valves (if they have been open fully). With a high pressured system it doesn't matter what tap you have, it should work fine. .. My guess is that he has probably put 'one way check valves' on the hot and cold pipework and this could be...
  14. yerino

    Strange: Two Radiators Not Heating

    It could be a number of things. 1) Your system might need balancing. (Eg, the rads that come on quickly and get hot need to be turned down and therefore pushing heat quicker to the other rads.. and do this with every radiator till they all come on at the same time. 2) You might have a...
  15. yerino

    Top half of New Rad Cold despite repeated bleeding

    If you turn off every other radiator in your house.. does your new radiator get fully hot then? .. If so, its a balancing problem. If the radiator still doesn't get hot, I'd recommend phoning up the radiator manufactuers and telling them your queries about the washers in the columns, etc.
  16. yerino

    New cold feed washing machine affecting electric shower

    If you look on your pavement outside there should also be an external stopcock (Under a little square flap). Check that is also open fully (might need to get down on your hands and knees to reach it!) :lol:
  17. yerino

    Strange: Two Radiators Not Heating

    Have you tried turning off ALL the other radiators with only your boiler on?
  18. yerino

    Faulty Flushing

    Won't be working for her again! :twisted:
  19. yerino

    Advise needed wrt gas pipe size.

    When commissioning the boiler he should have checked all the gas pressures. Inlet pressure, working pressures, burner pressures, gas rates, etc. If they are all okay, your gas pipe sizing is fine. Did he fill out the benchmark (in the back of your MI)?
  20. yerino

    1 cold radiator

    Can I just clarify you have done the following: 1) Turned off all the other radiators with your central heating on full. (Did your boiler cut off when you done this?) 2) Taken the 'cold' radiator off and flushed it through. (Was it dirty?) 3) When your radiator was off did you open up...