  1. P

    nic assessment

    AM1 was part of C&G 2360 when I Did it in the early 1980s
  2. P

    nic assessment

  3. P

    £320 to move one twin socket

    A friend of a friend has just been quoted £320 to resite one twin socket from one side of his lounge to the opersit wall, The electrician was asked if the quote included a test certificate, but the reply was "You have to organise that yourself" (putting Part P requirements in to the customers...
  4. P

    shower connecting

    Might require a 50a switch, depending on Kw size of shower,
  5. P

    TN-S mains supply

    These are minimum sizes for a 100a service fuse
  6. P

    yet another motor question

    FWL This is just for you DC injection and soft starts are another method, Just because you have never heard of it does not mean it does not exist, Looks like 2.5mm2 cpc in 6mm2 T&E cable is more commonly used than a 4mm2 cpc I have got a BS88 service fuse in my home, And have...
  7. P

    External cable help

    Try working with 300mm2 4core armoured in a tight space :shock:
  8. P

    RCD split boards

    I feel a bedtime story coming on 8)
  9. P

    Earthing isolator switch

    It's been a minimum of 2.5mm2 (Mechanically Protected), Or 4mm2 (Unprotected) since the 15th edition IEE Wiring regs, (Donkeys Years) :shock:
  10. P

    Earthing isolator switch

    Ditto Zoonie 8) That's what I thought too :shock:
  11. P

    Maybe a dumb question, metal plate switches

    Those sound cool 8) Where can I buy some of them :?
  12. P

    MCB siting

  13. P

    MCB siting

    Ahh? So landlords design electrical installations now eh? Or is it that they don't give a **** if their tenants are plunged into total darkness when there is 31ma of leakage on the fridge :shock:
  14. P

    BEWARE of Free Downloads

    Yeah you do...........369 trackers 8)
  15. P

    Cooker Socket/Fcu

    Hi Guys/Gals, I’m about to start a full rewire on a friends house, Part of the kitchen wiring requires a socket or fcu for the cooker, The cooker is gas and requires 230v for the timer & ignition, To the left of the cooker is a sink, So I can’t put a socket there, To the right of...
  16. P

    pulling out the few hairs I have left! - INSULATION RESIST.

    0.01M Ohms (10000 Ohms) From phase to neutral or earth would not trip an MCB or RCD, as the leakage current is only approx 23mA
  17. P

    NTL, And System Clock

    I have exactly the same problem with ntl, which is a b****y pain :twisted:
  18. P

    Where do we go from here?

    I believe the contractor is no longer in business :? I wonder why :shock: Think I will get "Registered", And stop paying my fees after the first year 8) But still use my van with the n****c logo for the next five years :twisted:
  19. P

    shower to fuse box

    That's why the word "should" was used :wink: