Search results

  1. P

    USA/UK Phone Chargers

    I Am Getting Married In Las Vegas Next Week 8) And I'm Taking My Bride, And Various Battery Chargers With Me To Charge My Cameras/Mobile Phone Etc :wink: The Camera Chargers Are Rated At 100v/230v Input, Which Is Fine For The American Voltage, But The Mobile Phone Charger Is Rated At Only...
  2. P

    meter leads and consumer units

    I Am Rewiring a House Where One "Service Fuse" Is Supplying Two Seperate Semi Detached Houses, The "Service Fuse" Is In My Customers House, Next Door Is Supplied Via 40m x 25mm2 Single Core Cables, With No Main Earthing Conductor Between The Two Houses, I Called In The Electricity Supplier...
  3. P

    Earthing a steel bath

    Just Saying :roll: You Know How The "Gossip" Goes About :lol: Hearing Things Do Not Make Them a Fact :roll:
  4. P

    Earthing a steel bath

    I Hear That Bathrooms Are To Become An "Earth Free Zone" In The Future :wink:
  5. P

    Wiring a Cooker point

    Minimum Is 4mm2 On a 32a Ring Circuit :twisted:
  6. P

    Site update

    I See That We Have Two "Car Forums" Now 8)
  7. P

    Re wiring guidance !

    "NICEIC" No Need For That Kind Of "Tone" Here Mr?
  8. P

    Wiring a Cooker point

    250kw Ramp Motors,
  9. P

    Wiring a Cooker point

    I Have Never Known a "Cartridge Fuse" Or MCB To Take The Hammer That a Rewirable Fuse Can Take (Under Controlled Circumstances), I Will "Call It a Day On This Issue" (For Now?)
  10. P

    Wiring a Cooker point

    Regulations (100) Insurance Comanys( 1000)
  11. P

    Wiring a Cooker point

    Have You Ever Had 50 People Hanging Upside Down On a "Suspended Looping Roller Coaster" For Over One Hour Because a "Cartridge Fuse" Got "Tired" And Gave Up Because It Was Closely Rated To Protect The Motors? The People On The Roller Coaster Put In Their "Insurance Claims", Which Far Outweighed...
  12. P

    Re wiring guidance !

    How Dare You Suggest That The "Smaller Ones" (The Self Employed) "May Recommend a Rewire As a Way To Generate Revenue" We Are Not All In The "Trade" To Make a "Killing" On One Or Two Jobs, As a "Professional" I Would Expect You To Choose Your Words More Carefully ?
  13. P

    Cable size for kitchen ring?

    I Recently Rewired An Arcade Using 4mm2 T+E Cable On Each 32a Ring Circuit Simply Because Of The Length & Loading Of Each Circuit, Even Though Each Circuit Covered An Area Of Less Than 60m2 It Was To Keep The "Volt Drop" To Within Tolerances,
  14. P

    Wiring a Cooker point

  15. P

    Permanently on lights (Urgent help needed)

    Now "Breezer" Let's Stay Professional Eh?
  16. P

    Wiring a Cooker point

    BS 3036 (Rewirable) Fuses Are Not "Outlawed" In Fact, They Are The "Prefered" Protective Device In a Lot Of Commercial/Industrial Applications Having Said That.......I Would Never Recommend BS3036 Fuses In The Domestic Installation, This Is My "1%" Diversity :o
  17. P

    Cable size for kitchen ring?

    Domestic Ring Circuits Are Wired With 4mm2 T+E Cable If They Are Protected By a BS 3036 (Rewirable Fuse), :evil:
  18. P

    Electrical shower installation "Please read this carefu

    109% Behind "FWL" On All One's........The 1% Is Allowing For My "Diversity" :roll:
  19. P

    It's Offical, Cable Colours to Change

    I Already Knew This "Ban", Just Like I Already Knew How You Would Reply, But You Missed The Main Point In Your Eagerness To Make Yourself Look Even More Stupid :shock: Keep To The Subject, And Not To The Individual Letters, :twisted: