Search results

  1. xdrive

    Chimney removal brickwork

    Stitch drill using sds then use chisel hammer function on sds.
  2. xdrive

    Using catnic lintel with existing timber lintel

    1.5years ago. Not signed off yet as I'm doing other work.
  3. xdrive

    Using catnic lintel with existing timber lintel

    Hi. I had dormers installed over year and half ago. The windows on the middle floor beneath the new floor are 2 metres wide. 3 to 4 joist of the new floor are sat on wall plate which is above window lintels. The load is only on the inner leaf however the wooden lintels are solid and cover...
  4. xdrive

    Mdpe water pipe

    Thanks. I have taken half a brick under floor to run the mdpe pipe into the extension from existing property wall. I'm also going to run radiator and hot water pipes in this hole. Is there are certain gap I need between copper and mdpe to prevent any damage from radiated heat?
  5. xdrive

    Mdpe water pipe

    Hi. I have replaced the lead water pipe for a blue one. I have a rear extension and the stopcock will go right at the back under kitchen sink. I have an extra 3 meters in length. Would you keep excess length under floor or cut it to exact length? If I don't cut it will it effect water...
  6. xdrive

    Single storey extension with warm roof require vented soffits?

    Plasterboard on ceiling joists. Insulated with 200mm of loft mineral glass insulation. Void then rafters with breathable felt, battens and double pantile tiles. 2 velux windows too.
  7. xdrive

    Single storey extension with warm roof require vented soffits?

    So is the roof style a cold roof? What would make it a warm roof?
  8. xdrive

    Single storey extension with warm roof require vented soffits?

    I phoned the building inspector. He said it wasn't required because of breathable felt. Confused now
  9. xdrive

    Single storey extension with warm roof require vented soffits?

    Does a single storey extension require vented soffits if I'm going to have a lower flat ceiling and put wool on them joists? Roof has roman tiles and breathable felt.
  10. xdrive

    Velux window leaking from underfelt?

    i know what i would do if i were to do it again. The cut should have been made a bout an inch below the corner and also 10 to 15mm from the corner. That would create a small channel directing the water away from the corner and towards the side.
  11. xdrive

    Velux window leaking from underfelt?

    No felt colour. Instructions don't show its needed.
  12. xdrive

    Velux window leaking from underfelt?

    Can't believe keylite instructions would suggest cutting like this.
  13. xdrive

    Velux window leaking from underfelt?

    I have fitted keylite windows in new roof. I built the frame and then cut the felt out, folded it above the frame and stapled it as per instructions. I poured some water on felt above the windows and the water pours out from top corner cuts. Also I have fitted the window including tiles...
  14. xdrive

    Gutter on a 15 degree pitch single storey extension

    Wouldn’t it be the same way it would get past the fascia board?
  15. xdrive

    Gutter on a 15 degree pitch single storey extension

    I have a felt support tray under the felt. The fascia wouldn't be able to lift tiles unless removed. So only option is to double batten. But the gutter position seems out. So I could remove support tray. Use facia to lift tiles and then have gutter sit in right position. would that mean...
  16. xdrive

    Gutter on a 15 degree pitch single storey extension

    Hi. I have a 15 degree pitched roof. I have just tried the gutter with the tile in position and it seems like the gutter is too low so if it rains heavy rain water may overshoot gutter. Here's a pic of what I mean and that's without putting second batten on bottom which I will add. I've...
Back