    Baxi 105e - high pitch noise

    After just over a month of singing pipes, it's back! Is there anything else I should check. Maybe I missed a o-ring or seal or something Very frustrating!
  2. A

    Baxi Combi 105e - hot water goes hot, cold, hot again!

    Cleaning the heat exchanger did work for about 2 months but the issue came back again. I cleaned it again early December while replacing the o-rings on the 3 way valve (separate issue) but so far no repeat of the hot & cold issue. If it does come back, I’ll give it another clean & replace...
  3. A

    Baxi 105e - high pitch noise

    Just to close the thread, I've replaced the 2 small o-rings inside the 3 way valve and at last no more singing pipes! This forum is amazing!
  4. A

    Baxi Combi 105e - New Heat Exchanger?

    Thanks tony, look like I'll be getting a new sensor tomorrow. The only thing I don't understand us why the faulty light does not flash all the time? It only flashes after running the dhw or when you disconnect it
  5. A

    Baxi Combi 105e - New Heat Exchanger?

    'suggesting', interesting word! I swapped over the CH & DHW sensor cables, we got warm water (not hot enough for a bath) but the boiler did not go out. The CH did not work though. Not really sure what this tells me!
  6. A

    Baxi Combi 105e - New Heat Exchanger?

    Just tried to run a bath, the boiler ignites and the first three LEDs light up (50C) then it goes out & the hot water led flashes again. It reignites and does the same thing over and over again! I think I'm going to try replacing the hot water sensor
  7. A

    Baxi Combi 105e - New Heat Exchanger?

    The led that flashes then goes out is the tap with a line through it. The dhw micro switch seems ok as when the push rod comes out the dhw led lights up straight away. Thanks Adam
  8. A

    Baxi Combi 105e - New Heat Exchanger?

    Thanks DP & Agile. I hope its not the PCB as I changed that back in June. Not sure what to do next, maybe you are right its time to call an engineer as the problem is intermittent. We've had some hot water today, the boiler fires fine & the water stays hot then next time we turn the taps...
  9. A

    Baxi Combi 105e - New Heat Exchanger?

    Hi I've got a Baxi Combi 105e and about 2 months ago was getting the hot water issue, the how water got warm, then cold, then warm etc. Eventually the water would not get hot at all. The hot water light on the boiler came on when the taps were turned on, the boiler would then try to ignite...
  10. A

    Baxi Combi 105e - hot water goes hot, cold, hot again!

    Unfortunately I get the same hot, cold, hot etc water issue with the taps! Any ideas please...
  11. A

    Baxi Combi 105e - hot water goes hot, cold, hot again!

    I think we do have the same issue with the taps but I'll double check tonight, cheers
  12. A

    Baxi 105e - high pitch noise

    I’m also now experiencing the hot, cold, hot water issue again! I cleaned the primary heat exchanger about a few months ago which resolved this but this issue has come back again! Is this related to the o-rings I need to replace? I’ve raised another post on this separate issue...
  13. A

    Baxi Combi 105e - hot water goes hot, cold, hot again!

    Hi My shower starts ok, the water stays warm but then it goes cold for a while and back to warm. I cleaned the primary heat exchanger about 2 months ago and it seemed to fix the issue until recently so I decided to do it again over the weekend. I gave it another rinse but there was no crud...
  14. A

    Baxi 105e - high pitch noise

    I'm really struggling which o rings to replace. Are the o rings external on the 3 way assembly valve as shown in this picture or inside the valve? or are they these ones on the inside/push rod?
  15. Untitled

    Untitled

  16. Untitled

    Untitled

  17. Untitled

    Untitled

  18. boiler

    boiler

  19. A

    Baxi 105e - high pitch noise

    I'm sure I got an overhaul kit before but could not get it back on with the new o rings so put the old ones back on! Thanks
  20. A

    Baxi 105e - high pitch noise

    Are all the o rings external, ie the ones connecting to the flow pipes or are there o rings inside the valve? I did replace the diaphragm earlier the year but decided not to replace the o Rings as I could not get the valve back on on with new o rings. How I wish I changed them now!