Search results

  1. M

    Baxi Combi desperate help please!!

    Look for silver loop and tell me what valves are like have they got black lever on or a slot for a screwdriver
  2. M

    baxi bermuda 401 back boiler problem

    I just repeated what the last fella told you to do sorry
  3. M

    baxi bermuda 401 back boiler problem

    Can you see the cable going to the solenoid which is behind the black plastic housing if you have 240 to there then its the gas valve gone down
  4. M

    No circulation to rads

    make sure auto air vent is open
  5. M

    Vokera Syntesi Losing Pressure

    It may be dripping inside the boiler and when the flames are on they eveporate the water so its a long shot but it does happen and why not try some internal leak sealer worth a dry before anything drastic
  6. M

    back boiler no heat and banging

    really so like the one i took out recently it might be letting a small flow through and the gravity circs are fine when c/h is on but when h/w only it bangs and clanks but with both on h/w is ok but heat is rubbish they drive you crazy some old systems
  7. M

    back boiler no heat and banging

    could it be fitted away from the back boiler normally within a few feet arent they but maybe its fitted upstairs as you say with it all drops
  8. M

    back boiler no heat and banging

    I looked for that first as i had that proplem last month no anti grav valve in there
  9. M

    down stairs heating not working, hot water and upstairs ok

    close upstairs and see if downstairs heat up
  10. M

    baxi bermuda 401 back boiler problem

    Just make sure the gas valve button is pulled out not stuck in when you lit pilot
  11. M

    baxi bermuda 401 back boiler problem

    What type of gas valve is on the boiler is it a grey button type?
  12. M

    back boiler no heat and banging

    Just been out to a back boiler which has gravity circs and the hot water is ok with the heating on but the rads dont get hot and if they turn the heating off for h/water only it starts clanking and banging now the pump is newly fitted by the customer and its all vented,water in the tank so what...
  13. M

    Myson Apollo Fanfare 40Si boiler problems

    Hello is it getting heat to the rads before it cuts out now if its reaching temp then trying to fire back up i can see maybe a pcb fault,see your boiler is telling the fan to run which allows the aps to open causing the ignition to start but when its sparking you say theres no 240 at the gas v...
  14. M

    Baxi ignition fault

    Mickyg would this be causing 24i worcster to fail to ignite most nights around 6-8 when gas is at its peak time the governor might be knackered,i apologise if i dismissed your reply before i will write this in my boiler book it will come in handy i bet
  15. M

    Balancing of radiators after new pump and 2 new mvs why?

    you do now but did you have it changed to a fully pumped,did you have gravity circs before did u have mzv 3 port or 2 port
  16. M

    Balancing of radiators after new pump and 2 new mvs why?

    Did u have gravity circs then get it all to a fully pumped system
  17. M

    Balancing of radiators after new pump and 2 new mvs why?

    Can you close gate valve then as the reason the rad is off the circs is to allow acsess heat somewere to go so the bathroom rad was the one,if you close the gate valve then unless the rad valves are stuck and no air in it it should be roasting
  18. M

    Baxi ignition fault

    It wont be the gas metre it will be the boiler so it could be (1) poor spark or may not work all the time (2) blocked gas injector not allowing enough gas through
  19. M

    Baxi ignition fault

    THE loud boom is the build upm of gas when its clicking its sparking but its not good enough to light the gas then when it fills with gas it will ignite thats the boom you will be hearing i think so anyway
  20. M

    Balancing of radiators after new pump and 2 new mvs why?

    Is it on the pipework co,ming off the cylinder were there top and bottom connections just close it a bit,and see if it allows the heat through to rad
Back