    Fuse for oven wall socket

    why change it? perfectly normal for oven to be on 13A FCU! 2900/230=12.6A what would you change it to?
  2. P

    Dimmer advice please.

    Hi, the rating of dimmer is max/min it should handle, since 7X50w = 350w it is slap in the middle of its range so should not be a problem. Presuming these are 230volt lamps and not 12v via transformer(s), if so then transformer system needs special type of dimmer. regards
  3. P

    wiring for new flexicom 15hx boiler

    further to what Petermack says, the reason is the new boiler requires the pump to 'run on' after boiler stops being 'called' to get rid off residual heat, boiler will have inbuilt overrun timer to do this. as he says you only need to take the pump Live from boiler but for new installations the...
  4. P

    hituf cable?

    traineelectrician, don't be put off by the negative knowalls , Hituf IS suitable for running surface 'clipped direct' as you intend, in fact it is suitable for ANY job SWA can do except buried direct in ground, if people are going to make such sweeping statements they should back them up with...