Search results

  1. D

    Combi boiler....water hot...then water cold...

    Ya I know... but as MsF didn't give a model number I just gave a generic answer to the boiler of my choice. :lol:
  2. D

    RAVENHEAT RSF 820/20 COMBI, CH Pressue Drop

    yeah... the suggestion was you have a leak... :lol: 100% definate, somwhere on the heating circs, the water has to be going somewhere, and as the DHW pressure is higher then the system pressure it sure as hell isn't going there.
  3. D

    Combi boiler....water hot...then water cold...

    crud in the dhw (water to water) heat exchanger. give it a few taps whilst running water through it should dislodge anything stuck in there
  4. D

    RANDALL 3060 replacement

    I can't remember... do you have gravity HW or not? erm...... LP722
  5. D

    Finger or something better?

    I have to admit to putting the ol' finger in once in a while, but I do try to use my little brush as often as possible.
  6. D

    whats the cheapest condenser boiler

    "This cover excludes but is not limited to any of the following, any fault caused by water, by the electricity supply to the boiler, wear and tear, and acts of god, considering that god is omnipresent and all actions and acts are therefore predestined by god, life is an illustion and your boiler...
  7. D

    Programmable Room Stat

    should be... ya.
  8. D

    Uncombining a Combi?

    I had somthing simalar to this a few months ago, a EcoMAX (28KW I think) Plumb the cylender in as a S plan style (include an auto bypass), and fit an external clock. That way you will be able to keep control over HTG/DHW. If possible try to retain as much of your hot water on the...
  9. D

    Boiler - very broken or meerly broken?

    without the model I wouldn't know if it was supposed to be running 24/7 or not, however I suspect it is supposed to run half speed for the pilot as you also thought. The pilot is there because heat on the thermocouple holds open the gas valve, the fan is spinning because it receives...
  10. D

    Wocester Combi Boiler - Hot Water fluctuates

    sounds like you have crud in your DHW heat exchanger, pop it off and give it a few knocks whilst running cold water through it that should dislodge anything stuck in there...
  11. D

    Ign cycling

    incorrectly positioned/faulty flame sensor / broken lead
  12. D

    Worcester 24i -V noisy after powerflush & new pump - Lon

    I normally find your problems with a Worcester in need of a flush... 'works its way through' ?? it didn't work its way through with a powerflush yet a 15/50 is going to clear it? they having a laugh? Your needle jumping/banging is due to kettling, Get the flush guys back... they've...
  13. D

    shower tripping

    Earth fault on the shower? (excuse my ignorance if i'm wrong but it would be what I'd check in that case)
  14. D

    pressure keeps going to 3 bar worcester924 elec

    Disconnect the filling loop... if the pressure still rises its likely to be your heat exchanger.
  15. D

    boiler over heating and hissing

    then kev is right on the money ;)
  16. D

    boiler over heating and hissing

    possible.. but then it wouldn't kettle unless he turned the water on and back off (unless its stuck fast of course.) and not at all while there is DHW flow.
  17. D

    boiler over heating and hissing

    A picture of the internals btw, I know what a white box looks like, :lol:
  18. D

    boiler over heating and hissing

    I don't have the diagram for a Pott Combi 80 to hand... nor have I worked on one for months.. (a picture would help tremendously if possible) Do you get the hot water? have you checked the pump? do you have a DHW heat exchanger? is the diverter opperating correctly? do you have a diverter? Is...
  19. D

    boiler over heating and hissing

    ya... check your pump you have a definate circulation problem, also run through the obvious checks, that you have water in the system, etc.
  20. D

    Moving a semi concealed Gas Meter

    I don't think you are wrong though. I'm almost 100% this would require Transco.
Back
Top