Search results

  1. D

    Some pictures from my collection

    Now you wouldn't touch this before checking it was dead. But this one bit me as the other end was connected to the lighting cct
  2. D

    How not to apply for a job

    I received the following text message today. Hello my names aaron jus wondering if u any jobs going i very greatful if u could give me one
  3. D

    form filling :(

    I use a customised word template with pull down boxes Form is in black with the bits you fill in in blue A unique numbering system and backed up on an external hard drive so I have no need to keep paper copies. I sought permision from Napit to insert their logo
  4. D

    What size cable..

    You calculate the maximum demand You apply diversity you have an answer of I amps now knowing, the cable length, type and installation method volt drop etc etc etc you look up the relavent table in the Eire equivalent of BS7671 and select a cable csa accordingly.
  5. D

    Main House fuse blown - what type and size to fit

    B&Q sell gas boilers QED
  6. D

    split load consumer unit

    I think MK website has not been updated this board http://www.tlc-direct.co.uk/Images/Products/size_3/MK5681ED17.JPG will comply to 17th depending on lay out of ccts
  7. D

    Kitchen wiring

    Don't buy cheap unseen products. I recently tried to fit some customer supplied sockets from a well known DIY shed and they were cr*p. The clamp screws were too narrow to grip wire properly and after taking twice the normal time to fit one I convinced the customer to take them back and use...
  8. D

    Would you mind if a client wouldn't pay till job complete?

    With all due respect to BAS we sparks have to make a living. I have terms and conditions that require (for large jobs) a deposit to cover materials and final payment on on completion. I also reserve the the right to withold issue EIC and notification until funds have cleared my account. NB...
  9. D

    The usual shed installation question

    60A switch fuse would protect feed to shed as you drawing shows no CPD. I'd use a metal clad switch fuse as it'd be a good to terminate SWA, tails from Henley block grommeted . How long is SWA ? Do pets come within scope of livestock?
  10. D

    MWC or EIC?

    My first thought was MWC but having just double checked regs and instructions for use of MWC Then EIC it is, although not fully defined I guess similar items means CPDs
  11. D

    Certification for consumer units

    Both a PIR and EIC require forms 3 & 4 appended to them. When I carry out a CU change I complete these two forms before old board is removed. As I reconnect each cct to new CU I double check IR readings. Once new CU is energised and of course any remedial work has been completed and...
  12. D

    Crimpers

    Up to 10mm sq will be a problem AFAIK I have a Draper set for insulated Red , blue & yellow and Kewtec for 10mm to 35mm (uninsulated).
  13. D

    Electricians forum

    Don't like the idea of entry based on post count as this would just allow those that talk the most to enter. I do like the idea of a more technical forum where topics can be discussed in depth but do understand that entry criterion could be seen as elitist if it's based on qualifications...
  14. D

    RCBO prices

    WF have a MK RCBO's for £21 + VAT until end of June for account holders.
  15. D

    17th edition CU

    TBH for 5 ccts I'd go with RCBO's as the split RCD boards are very large in comparison. Comms That link gave RCBO's @ £30.99 a go I'm getting MK ones for £21 at moment.
  16. D

    Kitchen ring mains, cable routing

    Speak to your LABC and explain what you are doing - you may find them helpful.
  17. D

    Help please need some advice on CU

    Could be redundant cooker cct But even if it is the current carrying capacity of the cable needs to be determined as induction hob and oven I guess will require more than 32A.
  18. D

    blade runner for cutting armoured cable

    Here's my penny worth on SWA Measure off where you want to cut the outer armour. Run a pipe cutter around cable so it puts a deep score in the armour (deep enough to be able to break strands.) Slide off outer insulation to expose surplus armour & break off. And finally lightly score...
  19. D

    Battery help

    For a sailboat with inboard you ideally need twin batteries and a split charging system. One battery for starting and a domestic battery for lighting and instruments. You will severely reduce the life of either battery if not used for correct purpose. Incidently what sailboat do you...
  20. D

    RCD trips on 'no trip test'

    What were the results of the full range of tests on the RCD as said before in isolation of any ccts. The Megger puts 15mA to earth on 'no trip' 3 lead test, so if for example if there was around 8mA of earth leakage on the RCD side of the board this would be sufficient to trip RCD