    Replacing 12v transformers with LED drivers

    Yes as long as the driver you have is earthed then all will be fine.
  2. R

    Part P amendment's

    Im probably about to stir a bees nest but I would like to know a bit more about the 2013 part P amendment's. what is a "third party registered installer", do sparkys have totame another exam in iexercise to be able to test other people's work? Who will the responsibility lie upon in the...
  3. R

    Replacing 12v transformers with LED drivers

    Can you cut a bit more of the outer insulator back to reveal more earth and then put a bit of sleeving on the earth and connect as normal? If your junction box doesnt have three terminals you can buy a new one from just about anywhere. You should also check the origin of the cable and make sure...
  4. R

    WANTED - 15cm of t-pren

    Thanks for the quick reply. I have a very shallow lead lined gutter that has a hashed lap joint and I would like to do a propped repair. How much would you want for some t-pren?
  5. R

    WANTED - 15cm of t-pren

    Im looking for 15cm of t-pren, if anybody has a little bit left over I will.buy it off them and pay postage. Let me know what you have.
  6. R

    repairing lead lined gutter joiny

    I have a lead lined wooden gutter, and what appears to be a bodge of a lap joint is open and leaking causing the gutter to rot. The lead doesn't appear to.habe any expansion joints or drips. I assume the only correct way to repair is to lap join and weld a piece if t-pren in. Am I correct or...
  7. R

    Electric shock from combi boiler radiator pipes

    I have a combi boiler (Vokera 28 Compact HE) and I have noticed when the boiler is on the pipes to the radiators become energised causing a small electric shock. Could this be a faulty pump (no shock when boiler isn't running), or is it likely to be something else
  8. R

    Fence exceeding 1m adjacent to highway

    I have just purchased a house, and have received a letter from the council stating the fence should be removed. I would like to know a few things: 1)Are they right in the letter? 2)What can I do as I cant find a photo older than 4 years? (Google maps street view has a photo that is 3...
  9. R

    repointing advice

    I've got a Victorian terrace house that needs pointing and I've decided to use a gun for speed. Will 1 NHL 3.5:2 soft sand:1 sharp sand be ok for pointing (some pointing is only about 4mm wide) and will it be ok going through the gun? Also are plastisisers or any other admixture advised...
  10. R

    Intermediate light switch problem

    Thanks flameport it all works perfectly now!!!! According to the labels on the terminals on the switch it was correct (i suppose I miss-understood them) Thanks everybody for your help.
  11. R

    Intermediate light switch problem

    thanks for your quick response viewer! I have switched the number 1 and 2 (2 way) switches and still ge the same results although i expected this as they were new switches. I have checked continuity wih my multimeter, between each wire going from each switch and found a break in the red...
  12. Untitled

    Untitled

  13. Untitled

    Untitled

  14. Untitled

    Untitled

  15. lights

    lights

  16. R

    Intermediate light switch problem

    Thanks for your replys everybody I have now replaced all the switches and still have the same problem. The faceplates are so dont want to take them off to take potos unless totally necesary. I have completed the table as requested I hope somebody can help 2-way #1 Inter 2-way #2 Light...
  17. R

    chimney leaking

    I have two lime mortar cchimneys one shared one not. Both of the chimneys are leaking badly when it rains water is running down the face of the chimneys in the loft and causing damage to the ceiling. From what I can see from the ground the flashing looks good but the poiting is bad What...
  18. R

    chimney leaking

    I have two lime mortar cchimneys one shared one not. Both of the chimneys are leaking badly when it rains water is running down the face of the chimneys in the loft and causing damage to the ceiling. From what I can see from the ground the flashing looks good but the poiting is bad What...
  19. R

    Intermediate light switch problem

    Thanks everybody for your replys? I will try new switches first because as far as im aware nothing has been touched.
  20. R

    Intermediate light switch problem

    I have 3 light switches to operate my lights, but im having problems when some switches are in certain positions either the lights are locked on or off unless the last two way switch is turned in the opposite position I have checked all the wiring against the wiki and it all is perfect, and...