    BAXI BERMUDA

    Jimhet, the vast majority of baxi BBUs have no overheat stat. These were only fitted to units on a sealed system.
  3. boabcelt

    Gamugate - illegal immigrant on X factor

    Actually I couldn't give a t@ss either way! I was just being a mixer :twisted:
  4. boabcelt

    Gamugate - illegal immigrant on X factor

    Aye... but you're letting facts get in the way of a good old daily mail rant!
  5. boabcelt

    Greenstar 24i CH OK, No Hot Water

    Disregard the post about a diverter motor. I think this poster is talking about a combi boiler, whereas it sounds to me like you have a system boiler. If you drained the system, you most likely have an airlock. You could try cracking open the nut on the flow pipework at the cylinder. Have a few...
  6. boabcelt

    Water only comes through hot if taps on high pressure

    It sounds as though the hot water diaphragm is perished. This is very common and is easily repairable. If you are not diy oriented, I would recommend getting an RGI in to effect the repair, and possibly to give the boiler a good service.
  7. boabcelt

    boiler ages

    The G.C. no. for a 401 is 44 077 49. Not too sure about the fire but it will be 37 077 somethingorother. Not exactly sure when the 401 ceased production, but the one I just removed was fitted in 1979! Nothing wrong with it either.
  8. boabcelt

    Conspiracy disgrace

    Of course it was all those evil catholics. They forced the British government, the Irish government,and the R.U.C. into the coverup. :roll: Regardless of who was involved, I hope there is a full investigation and prosecution of those responsible. Defeating the ends of justice anyone?
  9. boabcelt

    It takes a strong person..

    In the context of what the premier league players earn, the technology wouldn't cost much. However it would be prohibitively expensive for many lower leagues. Anyway, incidents like todays are and always have been part and parcel of the game. I rage away about them as much as the next guy, but...
  10. boabcelt

    Please Help 100cm2 Air Vent for Back Boiler???

    The vent needs to be calculated based on the appliance maximum heat intput e.g 16.8 kW for a 57/4e plus whatever the output for the fire front, be that 5 or 6kW.
  11. boabcelt

    Please Help 100cm2 Air Vent for Back Boiler???

    New under floor ventilation doesnt need to be ducted throughout its length if you can prove that space under the floor does not communicate with neighbouring property i.e. openings in the dwarf wall. Terracotta air bricks can be smashed out and replaced with plastic ventilator bricks of the...
  12. boabcelt

    Do You Know Of An Older Gas Boiler Than This Still In Use?

    A few months ago I was at a Halcyon Sugg warm air unit. Fitted in 1960 when the place was built. Cast ring burner on it.And a massive mechanical clock, like the old sangamo type with the perspex cover, so you could see all the cogs. They dont make em like that now. Thank god!
  13. boabcelt

    British Gas cover/noisy pump - what to do?

    Pretty much agree with all the advice you have received so far. Disregard what Axel said about the pump direction. From the pic there is no way of discerning the direction of water flow. The only thing which determines direction on that type of pump is the orientation of the body. There will be...
  14. boabcelt

    safety check gas fire

    Definately not a job for DIY. Minimum checks include operational and visual inspections of the flue, burner pressure/gas rate, ventilation, operation of safety devices, clearances from combustible materials, and then double checking the flue and ventilation! Fun and games at times. 8)
  15. boabcelt

    Gas fire and gas cooker in same room?

    W.U.M. Classic wind up merchant. Get a grip people :roll:
  16. boabcelt

    I want to ban ball type pump valves

    Tell me about it. I just changed a div valve on a 28CDi. Never touched the valves and when I re pressurised the system, both flow and return pi$$ed out! Boiler off the wall job :evil:
  17. boabcelt

    Baxi Solo PF Conventional boiler

    If you have open circuit between l and n, the coil is goosed. Tae use a technical term.
  18. boabcelt

    Worth fixing or possible to fix old Marathon Myson

    I think iep may be getting confused about what a gravity system is and what an open vented system is. To the OP, it sounds to me that you have pumped ch and a gravity circuit for your hot water. This was how many older systems were plumbed. It usually had 1" (28mm) pipework or larger going from...
  19. boabcelt

    Combi Boiler Exhaust flue

    If the flue is 2m or less from ground level it requires a terminal guard (wire guard) which has a minimum of 50mm clearance from all parts of the terminal. The position regarding openings into the building, boundaries etc also needs to be considered.
  20. boabcelt

    Boiler dead, do I need a whole new system?

    Danfoss do a full flow TRV which is suitable for single pipe systems. We just fitted 50 odd of them in a university building, along with 3 Hamworthy variheat condensing boilers.