Search results

  1. A

    Converting to combi pipework

    Rising main being the feed to the water tank, join the top pipe to the bottom feed pipe of the water tank? Even though I'll be capping it off and tapping the hot from the kitchen? So are you saying convert it to 15mm then cap it off? Any ideas how much of the hot will be in 22mm?
  2. A

    What system do I have?

    Apologies for the delay, thanks for the useful info If i were to keep the existing system, the upgrades you mention are these something I could do myself?
  3. A

    Baxi main calling for heat fault

    Removed the complete brass diverter assembly, fitted the small O ring at the back of the rear spindle, although there wasn't one fiited, all seems well now...
  4. A

    Baxi main calling for heat fault

    Found this, i didnt remove the complete assembly fitted the new diaphragm in situ. So it looks like i need to remove the complete unit, fit the smal O ring at the rear of the brass body and refit? https://www.diynot.com/diy/threads/baxi-combi-80e-leak.437674/ Is that correct?
  5. A

    Baxi main calling for heat fault

    Got a problem, there is a slight leak coming from the rear of the diverter valve, the bottom screw is tight but it appears to be coming from the hole in the middle, I thought maybe a screw got loose, but it doesn't look threaded Any ideas?
  6. A

    Baxi main calling for heat fault

    All sorted! The button on the microswitch looks like it had failed. Replaced the diverter valve as good practice, although the original one looked fine. Many thanks for your guidance! :)
  7. A

    Baxi main calling for heat fault

    Nice one! Thanks alot :)
  8. A

    Baxi main calling for heat fault

    Sure will do, is there likely to be a lot of water? Or a trickle?
  9. A

    Baxi main calling for heat fault

    Checked with the seller the part does indicate which wire goes where will also replace the diaphragm as the boiler is getting on a bit Will let you know how i get on Thanks
  10. A

    Baxi main calling for heat fault

    There are three terminals on the new microswitch if you search the forum for part no 248207 this matches the ad. Also provided pic of original part to seller he has confirmed it is 100% right
  11. A

    Baxi main calling for heat fault

    I've had it confirmed with the seller that it is correct via the gc number, will have to cut the wires as the wiring loom has other connections and costs a bit more
  12. A

    Baxi main calling for heat fault

    Apologies, it's a main combi 24 he Gc 47 474 02 I'll trace the wire and have a look, I've ordered the microswitch https://rover.ebay.com/rover/0/0/0?mpre=https%3A%2F%2Fwww.ebay.co.uk%2Fulk%2Fitm%2F283089521782
  13. A

    Baxi main calling for heat fault

    This is a three wire microswitch the wiring is integrated into it
  14. A

    Baxi main calling for heat fault

    I've looked at the microswitch/flow switch, opening the tap the pin pops out, closing the tap the pin returns back into the neutral position. Should i be hearing a distinct click when the pin hits the microswitch? as i didn't hear anything.. No signs of water ingress whatsoever either
  15. A

    Baxi main calling for heat fault

    Thank you for the helpful response, will have a look and report back, much appreciated
  16. A

    Baxi main calling for heat fault

    Not sure what the problem is asking here! There are several similar posts on the open forum!
  17. A

    Baxi main calling for heat fault

    Baxi main combi 24 HE Room thermostat is off, no timer is fitted to the boiler The dial on the boiler is set to hot water only but the central heating radiators are hot Noticed when running the hot water, the flame light comes on but when the hot water is switched off the flame light comes...
  18. A

    What system do I have?

    What's the difference between S W or Y plan? Out of the three what would you recommend and why? Would the above type of system be better than a combi?
  19. A

    What system do I have?

    Well I've had a plumber come up and he has suggested an ideal logic plus or vogue Combi boiler 35kw Is this a good boiler?
  20. A

    What system do I have?

    So should i upgrade the cylinder as you suggested or would it be better to rip the lot out and get a combi fitted instead?