  1. C

    No Hot Water - Ferroli Medone 80E

    First of all id check the flow switch.
  2. C

    Lockout

    The lockout probs have nothing to do with the fire valve in this case as youve stated it will fire up again after pressing re set button-fire valve would need to be manually re-opened.Listen to the burner when it fires up-if it starts to splutter b4 it goes to lockout it will be a fuel...
  3. C

    I wish I was a plumber!

    Theres good jobs and bad jobs in every trade,i went into the servicing/breakdown area ,with a few installs-now earning a decent wage and this time of year home for 2 most days,it took me just under 12 months to do gas course at college 1 day a week,onsite work another day a week-pass acs...
  4. C

    Potterton Profile 80e

    Work on quite a few of these but without boiler in front of me ahrd to find out what the wire is-if fan is running id rule out it being a fan connector,maybe wire to solenoid on gas valve??
  5. C

    Grant Combi boiler, rising pressure and overflow

    Check the pressure in the expansion vessel,i use a car foot pump,check MI but its usually about half a bar-if water comes out of the valve then it needs replacing-the prv will also most likely need replacing aswell.
  6. C

    is this a rip off?

    Did you agree to have that model fitted or were you not asked.As for bring ripped off it depends how much you were charged!
  7. C

    heatslave 15/19 oil-fired combi running out of dhw?

    its just a standard honeywell 2 port valve
  8. C

    heatslave 15/19 oil-fired combi running out of dhw?

    Goto go and look at a boiler sometime this week,only managed a 5 min check on it today cust complaining of hot water not lasting very long,flow switch,diverter valve seemed to work ok with thermostat set to max water wasn't that hot,a reducement of inlet pressure made it hotter but reduced flow...
  9. C

    Oil leak from nozzle

    Got to re visit a breakdown tomorrow.originally found oil to be leaking into combustion head and down to under controller box,fitted new nozzle with sealing compound as thread seemed a little loose,customer says its still leaking so it looks like its dripping out of nozzle,never had this prob b4...
  10. C

    CORGI assessment

    Had my corgi assessment a few months ago-was more like an informal chat than anything else-knew most the questions right off but ones i wasn't sure about,i just looked in the corgi book and answered them,the corgi bloke who did my assessment was great.
  11. C

    exploding lightbulbs

    We had 10 mains powered halogen downlighters installed in kitchen a few weeks ago the other day the bulb furthest from switch blew -causing a spark at switch and blowing fuse-tonite the bulb right next to switch did the same but this time the bulb itself exploded!would this be an electrical...
  12. C

    British Gas

    I was also told by them that although i was corgi reg i couldn't apply as i didn't have an nvq.After chatting to the bg blokes at the merchants who have 8-10 jobs a day to do where i only usually have im glad they turned me down! :D
  13. C

    worcester 19/24 cbi intermitent lockout probs

    One of our engineers went to a callout on one of these-boiler was dead,replaced pcb and got it working.Customers now complaining that it locks out-sometimes once a day-but other times can go a week working ok.Of course everytime i visit its working fine-replaced flame sensor today as i had spare...
  14. C

    worcester 15sbi intermitent lockout

    All burner pressures check out correctly,but by adjusting the softlite dial the inital pressure went up to about 5mb from 2.5mb so hopefully this has sorted it,was just not sure how long the flame rectification is given to prove the flame b4 it trys to reignite,
  15. C

    worcester 15sbi intermitent lockout

    loooked at 15sbi boiler today (lpg)which is aparantley locking out now and again but starting up again after reset button is pressed.As usually happens wouldnt lock out while i was there but burner would not ignite first time every try/flame would die down within a couple of seconds then it...
  16. C

    Oil heating problem

    By the overflow do you mean the prv??If so that will prob need replacing +the cause of it opening in first place will have to be identified.As for the smoke part of your problem it will need a service-the oil pressure/air damper needs setting up with a flu gas analyser.
  17. C

    Potterton Statesman oil fired boiler - lock out

    You checked the oil filter??ive ben to a few which lock out after while then wont re-start for a certain period,faults on a couple of these were the fact that the inline oil filter was clogged up.
  18. C

    Age old glow worm burners

    If you find a burner with a crack in it but the boiler is still working ok-crack having no affect on flame picture are they ok to leave running or they need condeming?
  19. C

    Pressure switch on Potterton 60e not switching.

    Might be fan on way out-not giving the aps the desired pressure,or if fans ok may be faulty aps requiring to much pressure to activate it
  20. C

    tracpipe

    The "course" is reading through a tracpipe manual and answering questions-u then get a crappy paper card sent through post to say you can install it-i doubt ill ever use it.