    What happens in a Part P Inspection?

    I guess that could be right, but most connections don't (shouldn't) get that hot. Or perhaps small temperature changes can have the undesired effect? Maybe it's time we moved beyond screwed connections? Any ideas for the Dragons' Den? :D
  2. T

    What happens in a Part P Inspection?

    Interestingly, well over 50% of all screwed connections I check are loose. I'm always tightening things up on every job I do (but not too tight). However, I've been surprised at how little tightness is sometimes necessary to allow an electrical connection to function. For low power devices...
  3. T

    supply to garden office / log cabin

    If you're using 4mm² T&E, why not stick it on a 30/32A breaker? If 20A is plenty for the foreseeable future, then just run the radial in 2.5mm²: it's a lot easier to work with :D
  4. T

    Oven/Hob set up

    A 'tad' slow this time, eh? :wink: No bother at all :D
  5. T

    Oven/Hob set up

    Should be fine. Did I get there first? 8)
  6. T

    Oven/Hob set up

    Once again, didthathurt, you beat me to it, you lightning-fingered spark :lol:
  7. T

    Oven/Hob set up

    The MCB will have to be rated to protect the smallest cable in the run, which is 6mm², in other words 45A if it's burried in plaster or clipped direct , or 32A if it's run in conduit, within or without the wall (38A is maximum capacity in this case, so you have to go to the next lowest size of...
  8. T

    Crimping cables

    Are they just regular crimps? I have recently used some 'heat-shrink butt crimps' and they're brilliant: very strong mechanically and sound electrically. They look professional, too, more so than just plain crimps.
  9. T

    BIOS disaster!

    That's a relief! When I say 'fiddled about', I think I just set the time & date, the boot sequence, and one or two other very minor things. Certainly didn't get too out of my depth! :D However, I am still left wondering what caused the problem in the first place, as this PC had been...
  10. T

    Macerator

    OK, seriously, in the house I live in there's a VortoPlast 1, made, I think, by Ceramica Italia (so therefore not French). It's in constant use by 5 people and seems very reliable (OK, I'm tempting fate now). However, the sink or shower don't go through it, only the loo pan. Maybe this makes a...
  11. T

    BIOS disaster!

    Latest update, if anyone's still watching.... Did the following, but not necessarily in this order: Disconnected then reconnected the CMOS battery. Removed all the memory (four sticks of 1GB each) Replaced stick in slot 1 (actually, swapped it out first) Rebooted Got to the familiar...
  12. T

    Macerator

    Tempting fate a bit there, SS....I give it about 2 days (better make sure she's got some Marigolds :lol: )
  13. T

    wiring new hob and double oven from single supply

    :lol: Like it! (a Scotsman abroad who misses real civilisation...)
  14. T

    New Cable needed??

    If I may come in here, gents (you guys may want a break from this one!): To the OP, can you tell us what exactly the power rating for each item is? I imagine the hob will be about 6kW, therefore drawing around 25A max. The oven, around 2kW, drawing about 8A. That would be a total of 33A...
  15. T

    Please explain ....simply

    Hmmm...that last reply was for the OP, Penny :roll: . Bloomin' hijackers...
  16. T

    Please explain ....simply

    I'm sure I speak for all concerned in saying 'you're very welcome & good luck' :D Fingers crossed you won't need to have your floor ripped up. Having said that, it goes with the territory for plumbers & electricians. Stuff is always behind a wall, under a floor, above a ceiling!
  17. T

    Please explain ....simply

    How are you getting on with all this, penlopej? Hope things are a bit clearer.
  18. T

    Please explain ....simply

    Welcome aboard gentlemen 8) .
  19. T

    Please explain ....simply

    Ah, great minds, etc.. :lol:
  20. T

    BIOS disaster!

    Thanks for all that, guys. Been a bit too busy lately to get in there and start wheeking out RAM, etc. I really don't think trying another version of BIOS will work. It's tried to flash the original version and the latest version, both with no luck. If it's the mobo, I'll be extremely...