Search results

  1. Bigsosij

    Scantronic lid tamper engineer reset

    It is retained in the non-volatile memory
  2. Bigsosij

    Install cable and socket to extend router connection. Which remote faceplate?

    Soon you will get fibre and it will have all been for nothing
  3. Bigsosij

    Easy stick LED Security Lights ?

    U tried BnM's lol
  4. Bigsosij

    Pyronix DELTABELX Battery change

    Type FP03750 in to google
  5. Bigsosij

    Texecom premier elite arming message

    Try system config hide armed areas - change to view armed areas
  6. Bigsosij

    Pyronix Euro 46 Tamper on Input

    Looks like it had tape over it in first pic he posted
  7. Bigsosij

    Pyronix Euro 46 Tamper on Input

    What happens when u try and set with the kitchen zone as unused ?
  8. Bigsosij

    Pyronix Euro 46 Tamper on Input

    2k2 is fine, tamper should clear when there is no movement in the room. 8k8 is too high should be 6k9 OC. Could try taking the jumpers off and fitting 2k2/4k7 resistors in the terminals
  9. Bigsosij

    Pyronix Euro 46 Tamper on Input

    Try it without the cables connected to the pir. Should be open circuit with the button not pressed
  10. Bigsosij

    Pyronix Euro 46 Tamper on Input

    It doesnt have a back tamper, u need tp check the resistance reading on the blue and yellow if it still showing tamper with the spring pressed down
  11. Bigsosij

    Extend wires from control panel to sensor

    That escalated quickly
  12. Bigsosij

    Getting Engineer Access to Texecom Premier

    What he's saying is that there is a video showing u how to reset the code on texecoms own youtube channel. Not very professional behaviour if u ask me.
  13. Bigsosij

    Veritas 8 chimes issue

    Will be whatever the engineer set it as
  14. Bigsosij

    Accenta g3 alarm won’t set but battery is new,

    You will need to identify the wiring for the zone that has been removed and disconnect it from the global tamper circuit. Assuming this is the only tamper fault currently present then the system should then reset.
  15. Bigsosij

    Eurosec CP8L - Replace magnetic door contact and panel battery

    No voltage on door contact wiring so don't have to worry about blowing any fuses
  16. Bigsosij

    Pyronix HomeControl 2.0

    On the home screen before u connect to the alarm
  17. Bigsosij

    RJ11 cable faulty - how to detect

    Perhaps the socket/adsl filter/incoming line is damaged
  18. Bigsosij

    Pyronix ProControl+ App - stopped communicating

    Yeh so have I bit it's not letting him login so credentials must be incorrect
  19. Bigsosij

    Pyronix ProControl+ App - stopped communicating

    It's deffo polling I would double check that user code and app password
Back
Top