Search results

  1. M

    Visonic panel advice

    Will do, thanks Matt, just to confirm though if you can remember when dealing with them - you don't have to use any monitoring service to connect via the powerlink do you? Just point the app at the panel thru your home router?
  2. M

    Visonic panel advice

    Thanks E999, do you know what you can actually do with the powerlink2 module fitted as details on the net are like rocking horse poo!
  3. M

    Visonic panel advice

    Hi all, Currently looking at completely wireless systems for a traditional 3 bed domestic semi, and interested in the Visonic range as research so far seems to indicate they are particularly well thought of. I've been looking at the following... PowerMax Complete PowerMax Pro...
  4. M

    Texecom Premier 48 intermittent Fire alarm on entry!

    Well yes, as above I reprogrammed so it has the omit attribute so I can't understand why I am still unable to Omit! Maybe it doesn't 'need' doing but if I should be able to omit, I want to understand why I can't !!!!! The detector has been cleaned but it was spotless anyway. Not sure if it...
  5. M

    Texecom Premier 48 intermittent Fire alarm on entry!

    It was going off on entry - or at least all hell breaks loose at the keypad but couldn't tell if the sirens were wailing outside (didn't check tbh). No problems for a few days since the garage was cleared and the detector covered, until a strange one today. I was actually in the garage and...
  6. M

    Texecom Premier 48 intermittent Fire alarm on entry!

    Thanks for the reply Hoover. No changes recently, to wiring or detectors. The smoke runs to a keypad zone but the front door runs to a zone on the main panel. I'm nowhere near the property at the moment but from memory the sequence of events has always shown a fire event when the...
  7. M

    Texecom Premier 48 intermittent Fire alarm on entry!

    Thanks for the reply. Not really near a door, and not very dusty either but I've gently blown a bit of compressed in and around just in case. I have left it covered over for a couple of days to eliminate environmental factors. Doing a bit of digging though the activity logs, it appears...
  8. M

    Texecom Premier 48 intermittent Fire alarm on entry!

    Hi, I installed a Texecom Premier 48 a couple or three years back, keypad in the house and an additional keypad in the garage. I used the ability of the garage keypad to run a couple of extra zones, one for the doors and one for a fire detector (M12). All has been running tickety-boo...
  9. M

    Using one alarm to trigger another

    Well... not quite what I was hoping for ! Couple of issues, which I think is just how the system works rather than my programming. As I thought if I put the House & Garage into different areas with their own associated keypad, I don't get the entry/exit tones on the other keypad which is...
  10. M

    Using one alarm to trigger another

    Unfortunately though I don't have the computer interface !!!! Bu**er ! :cry:
  11. M

    Using one alarm to trigger another

    Thanks, will take another look... Though I think option 1 might be out because (as I understand it) putting the keypads in both areas means I'll get sounds on the house keypad when arming/disarming the garage ? I guess this is where the computer interface option comes in handy - I presume...
  12. M

    Using one alarm to trigger another

    Thanks for the reply - on a Sunday too, don't you have any time off ? :D I'll look into both options, but just so I'm going in the right direction from the off, is this using "Keypad Areas" (p57 in the manual if you have it handy) or using "Area Arm Suites" ??
  13. M

    Using one alarm to trigger another

    Well that was a moring and half the afternoon wasted ! :cry: Still struggling with getting it to do what I want. Think I need to ask some more basic questions to make sure it can do what I'm trying to get it to do.... The keypad in the house is in Area A only, as are Zones 1-8 The...
  14. M

    Using one alarm to trigger another

    Yes, that was fun for a while ! luckily I hadn't reconnected the batts in the external sounders but I pulled the 12v to them so just had to contend with the speakers warbling away whilst I hastily scoured the manual and hammered away on the keypad !!! :shock: I think I disabled it by...
  15. M

    Using one alarm to trigger another

    So far, nearly so good ! All went well until 1st test when managed to trigger alarm and then couldn't silence or reset it - wanted a fob to disarm. Eventually managed to silence it somehow, and I think I've found relevant option to disable that. Now I'm just sorting out some glitch with...
  16. M

    Using one alarm to trigger another

    Aha! I swondered what I could use that output for !!!! 8) Thanks for the reply !
  17. M

    Using one alarm to trigger another

    Sorry to give this a bump, can anyone advise on my last question ??? So close to getting it all connected ! Cheers
  18. M

    Using one alarm to trigger another

    Hi (Re)wiring going ok, taking a little longer than anticipated though ! Quick question re connecting extension speakers if I may which isn't clear from the manual.... Wiring one in for the house from the control panel is fine, there are 2 terminals maked 'SPK+' and 'SPK -' I wish to...
  19. M

    Using one alarm to trigger another

    ps I don't think I can change the title of this topic can I ? Its gone way beyond my original question !!!!
  20. M

    Using one alarm to trigger another

    Hi there, Hope you are all well and nicely rested after the festive period... cos I'm back !! Just to give an update, I've now got all the bits n pieces I need and have started wiring it all up where possible. Adding the resistors in is a bit fiddly at the moment but I'll get it sorted...
Back