  1. G

    Cavity floorbox in a solid floor

    Sounds like a good idea to me. I have installed floor boxes in a concrete floors before it was a messy job. I used an angle grinder to cut the hole. I would install a couple of tubes for future use though. G.T.S 8)
  2. G

    Had a custom distribution board built

    Is it me ? or is that a single phase busbar connecting all three phases of the RCD together and a noticeable lack of a neutral FFS what a pile of sh1te G.T.S 8)
  3. G

    is it possiable to add timmers to storeage heaters?

    Storage heaters require 7 hours charging at night to work properly if they dont get 7 hours they dont stay hot all day. You can add timmers but the heaters wont stay warm for long due to them being on for only 4 hours G.T.S 8)
  4. G

    Tamper proof roomstat

    why not just buy a proper tamper resistant stat http://www.uk-plumbing.com/sunvic-room-thermostat-tlm2453-p-42309.html G.T.S 8)
  5. G

    void testing?

    Basically it means testing empty propertys mainly rented ones when the tenants move out you have to carry out a PIR before a new tenant can move in. Thats it G.T.S 8)
  6. G

    Foot operated dimmer switch

    I would take it back to Ikea but .......... B&Q do sell the foot operated dimmer switches they arn't cheap though the last one I brought was about £15 G.T.S 8)
  7. G

    thermostats

    thanks ricicle couldn't remember G.T.S 8)
  8. G

    thermostats

    You Must not use a cpc as a live conductor you have to use a 3core and earth cable if the thermostat requires live, switched live and neutral some thermostats don't require a neural just live and switch live some thermostats have a little heater thing not sure of its proper name but it...
  9. G

    alpha combi boiler

    Why? the stat is part of the boiler wiring and if you install the spur on a ring main then there will be two input cables why? that way you end up with 2 cables my way you have one and it looks neater Just my opinon G.T.S 8)
  10. G

    alpha combi boiler

    I wire alot of valliant combi boilers I run a 2.5 t+e cable from the mains board to a spur by the combi then i run a 1mm three core from the stat to the spur then i run a five core flex from the boiler to the spur thats L N E for the boiler then live and switch live for the stat Then in the...
  11. G

    Megger

    It will do Continuity readings so it will check your main bonds and your R1+R2 of your circuits and your ring main end to end And it will test insulation resistance between L-N L-E N-E You must make sure that it is calibrated if you are going to be using it to carry out Testing for...
  12. G

    Whats wrong with This?

    Yeh there was but it was switched on i just disconnected the cooker from the wall and put a cover plate over the connections and all was well then its the tenants responsibility to get the cooker repaired
  13. G

    Whats wrong with This?

    Not sure all i can think is that internal wiring had gone due to the reverse polarity or one of the elements had gone but with the cooker connected it tripped the RCD with the cooker disconnected the RCD not trip
  14. G

    Whats wrong with This?

    alright Smart arses had a busy day on callout and forgot my camera had to use my phone 1 Theres no cover plate or cable restraint on the connection unit 2 And if You look carefully you will notice the fool who connected the cooker up connected it up incorrectly hence the incorrect...
  15. G

    Whats wrong with This?

    Went out to a callout tonight the job was the no power to the property I found out that it was the cooker but whats wrong thats as found
  16. G

    beeny carcassing

    Yeh saw that Id love to know if she is a registered installer to comply with part P and all is it just me or are these people daft not listening to her advice wot about that useless garage G.T.S 8)
  17. G

    Self-Adhesive Trunking?

    Sticky back trunking is no good for fixing trunking properly. After a while it will loose its stickiness and drop off I always use sticky trunking because its easier to fit because you can stick it to the wall and make sure it looks good and strait then i drill and use screws to fix it properly...
  18. G

    Ideas needed

    Microphone cables i'm hardwiring microphone and speaker points throughout a old building which was rewired by cowboys G.T.S 8)
  19. G

    Ideas needed

    its in capping about a foot further across from the socket below i did try to pull the cables but they were stuck so carnt pull new cables in i think i will go with nozsparks idea by using a double surface box and blank plate
  20. G

    Ideas needed

    good ideas just wanted to see if anyone had any other suggestions G.T.S 8)