    Ariston Eurocombi A23MFFI- Hot water probs

    Okies, bump. Symptons have changed again :lol: Its now working again in DHW only mode, but once more has the crappy hot water issues & the DHW diaphram is moving as opposed to still as it was previously. Only change is that the boiler is warm (Heating has been running for an hour or so)...
  2. L

    Ariston Eurocombi A23MFFI- Hot water probs

    I'm well aware of which is which in terms of the two diaphrams :) DHW diaphram is the larger one with a pushrod attached. The main flow switch diaphram is much smaller and mounted on the three-way valve. Trouble is that I'm not sure what the main flow switch diaphram & microswitch is doing...
  3. L

    Ariston Eurocombi A23MFFI- Hot water probs

    My poor head :lol: There's a 3-way valve, with two microswitches attached. Microswitch 1 is on the right hand side, and is operated by the DHW diaphram. When the boiler is on DHW mode only, this diaphram doesn't even move. Turn the boiler to heating/ DHW mode, this diaphram operates, pushing...
  4. L

    Ariston Eurocombi A23MFFI- Hot water probs

    I think I need a wall to beat my head on :P I've now changed both diaphrams & the temperature probe in this wretched thing. Secondary heat exchanger is clean as a whistle. The symptons have now either changed though, or I may have been wrong in the first place. I can't get any HW at all...
  5. L

    Ariston Eurocombi A23MFFI- Hot water probs

    Don't ask me :lol: Owned this house for 9 months, HW has been getting worse for a while now, but I've never got round to doing anything because there's an electric shower. All I can say is that the boiler was serviced relatively regularly for at least the two years before I got the house, as...
  6. L

    Ariston Eurocombi A23MFFI- Hot water probs

    Right, what would be a suitable descaler? Kettle stuff? Also got a large bottle of bleach floating around, would this be suitable? Heating wise, there's a Sentinel X100 sticker on the side of the boiler (Dated 1997) I don't know how regularly things have been serviced/ renewed, but water out...
  7. L

    Ariston Eurocombi A23MFFI- Hot water probs

    Not a real boiler man, and no qualifications as such. Have also been consulting with a friend in Cornwall (Corgi fitter), & his opinion was diaphram/ thermistor. Have obviously changed both of these with no change, and so his opinion without seeing the boiler was now main flow switch, which...
  8. L

    Ariston Eurocombi A23MFFI- Hot water probs

    Hiya, Got an Ariston Eurocombi A23MFFI here (Can post the GC number if that becomes necessary). Got a problem in that hot water is only being provided at low speeds; Turn the tap on more than a small trickle & it goes cold. So far I've changed the DHW diaphram & the thermistor with no change...