    glowworm microm 60ff boiler

    Its not a combi, you turn water only on the programmer. If it wont do that then its the motorised valve as he said.
  2. P

    Installing acrylic bath securely

    Brackets have to be secured to bath battens and the fixed to the wall on one side and the end. A frame is needed to take side panel and make edge more secure if it is sat on or stood on. the feet have to be screwed to the floor once bath is levelled.
  3. P

    Do I need a new radiator?

    Following up from brassedoff It sounds as if the gland seal on the valve spindle was leaking. This would show itself by leaking from the small round brass spindle just above where it is going into the body. If the plumber has repacked the spindle with ptfe tape it wont leak until someone turns...
  4. P

    stinky bathroom

    The shower should have a shallow trap under it. This will allow enough water to be left in the trap to stop smells coming up it. If the water is being sucked out by another piece of sanitary ware like a sink emptying then that will cause the smell. you need to check for how the waste water runs...
  5. P

    new soil pipe reducing 110mm to 82mm

    110 is smallest so should really reduce since there is a risk of a bottle neck blockage.
  6. P

    H/W entering F&E tank through system feed pipework? Any

    Or may be caused by the pump being put on the wrong way round, make sure the flow pipe on the boiler is the pipe that gets hot first when boiler switches on.
  7. P

    CH off but radiators getting hot when water heating

    You need to get someone to look at it the picture you show is called a tundish and it means the pressure relief valve is discharging may be faulty valve or pressure to high or expansion vessel needs the air in it re pressurising, you also have a motorised valve that is not working properly.
  8. P

    Problems with Mcalpine Non return valve

    Try changing it, the washer may be weak.
  9. P

    HW only comes on for a few minutes. CH is fine

    You must have a bypass loop that tees off the flow pipe between the pump and the valves, and then it goes to the return pipe on the boiler. It should have an automatic bypass valve on it but it probably has a gate valve with a red wheel, try closing it and see if that helps, if it does then the...
  10. P

    HW only comes on for a few minutes. CH is fine

    By pass loop is letting water through and that is more time consuming for me to answer, when boiler fires up before it switches off is the return pipe to the boiler getting hot when it should still be cold?
  11. P

    Toilet cistern side entry ball valve doesn't shut off

    Turn off the water to the ball valve, remove the large knurled nut, inside there is a diaphragm washer, replace it with a new one for about £.50 and jobs done, easy to repair old style, not so easy to repair fluid master. Buy a new washer first.
  12. P

    HW only comes on for a few minutes. CH is fine

    You may have an air lock in the top flow pipe to the cylinder, if there is a manual vent on the pipe, open the cap half a turn let the air hiss out, when water comes close it and it should be ok, as long as the motorised valve is opening for hot water. If it is a 3 port valve it will be open by...
  13. P

    Problem shutting off hot water, at one tap only.

    It is best to drain from the ground floor tap 1st if you have turned off a gate valve (red wheel) then they are not reliable for turning water off completely. You may need to put a rubber tapered bung in the cold outlet to hot water situated in near the bottom of the large tank in the loft. You...
  14. P

    Replacing HSV3 valve

    Yes can do always check thread compatibility 1st, by testing nut on new one.
  15. P

    Baxi 105e (not instant) hot water fault

    Have you looked at page 39 of the manual, fault finding chart for hot water?
  16. P

    Looking for obsolete Potterton Kingfisher CF220 t

    Repost once a fortnight and you may get lucky with one of us scrapping one, I did 18 months ago.
  17. P

    Boiler/Thermostat Problem

    Change the radio stat to a different one.
  18. P

    Worcester Bosch 35cdi Loosing Pressure

    Check expansion vessel air pressure is 3/4-1bar with zero pressure in the system. Have you got too many rads for size of expansion vessel?
  19. P

    Heating turned off but it still comes on

    As Dan said we need info, like is a combi or open vented, is it fully pumped open vented or gravity hot and pumped heating. Have you got a programmer or not. Get the idea?
  20. P

    Water pressure, lack of and a solution?

    Phone the water board, they will check it outside, it has to be a minimum amount, and there may be an external leak causing it. Its a free service.