    Condensing boilers.

    Can someone give me a model/make which only requires a RGI to check the CO2 only, and not CO and CO2 with a telegan. Cheers
  2. C

    ideal c28 mini going to lockout

    Could be PCB, or gas valve. Went to one once which had explosive ign, so much so it blew the top off the flue!!!! Turned out it was the gas valve. As above, if you can smell gas, something isnt right, far from it!
  3. C

    Determining a DFE and a LFE fire

    thanks Kirk Gas, I agree, when its a basket style etc, its fairly easy, but i have trouble when you walk in, and there is either an inset DFE, or an inset LFE. Apart from the flue spigot being applicable to the latter, are there any other way???
  4. C

    Determining a DFE and a LFE fire

    Ok, Apart from the MI's, or in the case of a DFE, being able to look right up the chimney with the fire in place, what other ways are there to tell if a fire is a DFE or LFE, if they are inset???? I find this really hard to do, yet some people can tell right away just by looking at it.
  5. C

    Calor Propane gas usage

    Its used 3 weeks over christmas, and the rest during spring - autumn. The caretaker wont be heating the house up all day. In the winter it ison for perhaps a max 2 hours a day to keep the place warm and stop burst pipes etc. DHW will be off. Of cource when they are there its all guns...
  6. C

    Calor Propane gas usage

    apart from calor anf flogas, who wlse is there??? Is there a website like u-switch for tank propane?? Cheers all, great help.
  7. C

    Calor Propane gas usage

    I didnt know that, i thouht you were stuck with one supplier ad thats it. I will look around, cheers.
  8. C

    Calor Propane gas usage

    Hi all, Just need some general advice frim all you knowlegable folk out there. Property, Large house, as in 10 bedrooms all on-suite (ex hotel), Large living room, through dining room, kithen, family room, offices, a further 4 bathrooms, and a couple or more rooms. All in all a large...
  9. C

    Halogen lights

    ignore my first post, Under the rose, i have 3 wires, a earth, a black and a red. SO would i be right in wiring red to live, the black to the whites, and earth to earth. Cheers.
  10. C

    Halogen lights

    thanks guys, here some more info from the sticker inside Ring Lighting, Leeds, England, Model No. 51319, 240v -50hz, 2xMAX.50W GU10, then it has a CE mark, then an upside down triangle with an F in it, and another wierd symbol which looks like a semi circle, with 3 dashes coming from the left...
  11. C

    Halogen lights

    Evening all, Hopefully a quick question for you all. IN my bedroom, i have a simple bulb connected to a 2 core wire (Brown and blue) hanging from my ceiling. I was given a 3 bulb halogen fitting, which has a terminal block inside, but the colours are as follows, The first connector...
  12. C

    Vokera Linea Max burner repeatedly starting and stopping

    Check the air pressure switch, and also the venturi in the fan!!! and ensure tubes are connected to it. You will probally need to remove the fan to get the venturi out!
  13. C

    Vokera Mynute 20SE

    So, anyone want to take a stab at the possible issues wrong with this then? Its either the switch which i doubt, but i will test today, or the pcb. ANy others?
  14. C

    Vokera Mynute 20SE

    your right, when its off if i recall, the pin is all the way out, but when fired up, the pin goes in and turns the switch off i believe.
  15. C

    Vokera Mynute 20SE

    OK, i am some where nearer to finding this fault. As above, checked the pump and its defo is ok. So, I downloaded the fault finding flow chart from vokera and did the following Check 240Vac coming in - Yes Turn on mode selector switch Does pump run - Yes 240V on 1 of boiler stat -...
  16. C

    Vokera Mynute 20SE

    Excellent, i will do all 3!
  17. C

    Vokera Mynute 20SE

    OK, I will do this tomorrow then. If it is working, what would you put your money on? I dont have a fault finding flow chart so its a bit hard. As it isnt even trying to spark, it must be either the ignition or the pcb.
  18. C

    Vokera Mynute 20SE

    APS is cool, checked resistance and it is making and breaking ok, and the voltage is cool aswell. I didnt take the bleed screw all the way out as i can feel the pump working and hear it humming away when i hold a screwdriver on it and to my ear. I have my ACS, but I am dont have much...
  19. C

    Vokera Mynute 20SE

    HI All I have a Mynute 20 SE system boiler. No R/S etc, just a mechanical clock on the front. With the boiler turned on, and the programmer on, it wont light. So far I have determined. Pump Runs (Slightly loosened the bleed screw and felt/heard it run) Fan Runs (Can hear it)...
  20. C

    FGA

    why not just stick the probe 200mm up the flue from the down draught diverter?