  1. McCombi

    POWER FLUSH WORTH THE MONEY??

    Is this a price from Worcester Bosch direct? Or a registered installer? How big is house?
  2. McCombi

    24 Dec - update - Grundfos pump still runs constantly

    Strange one. If wiring issue, why would it be ok for a day or two before faulting?
  3. McCombi

    Help with Boilermate OV A-class

    These Boilermate’s didn’t have a mixing/blending valve on them like the earlier ones. Do you get scale where you live? Possibly scaled domestic plate heat exchanger or a mixer tap somewhere in property faulty and passing cold water to all taps.
  4. McCombi

    Magnetic filter fitted loose

    Don’t think I’ve ever came across one that isn’t leaking to be honest. Get it swapped over for a brass one.
  5. McCombi

    Setting 3rd on/off time

    Not sure on that model but there’s usually either screws on top or bottom to loosen and programmer will come off of a backplate. If no screws there will maybe be a couple of slots to get a small flat screwdriver or similar into to prise off. There must be something or how would installer...
  6. McCombi

    Nest thermostat - boiler issue

    With that boiler, if happening as frequent as that, it may not be nest related at all. Get a registered gas engineer in to look at boiler.
  7. McCombi

    Nest thermostat - boiler issue

    Could just be your boiler thermostat is set a bit lower than it was previously and is coming up to temp before nest set temp is reached. Is the nest in same place as old one was? Maybe the old stat wasn’t readings temperatures bang on ie degree or two out, maybe the nest isn’t calibrated...
  8. McCombi

    Suspect Motorised Valve on Central Heating

    if the ch 2port isn’t motoring across then valve itself may be passing. The whole valve body can be replaced or you can get service kits for changing internals only. They can wear down over time or get muck preventing them closing properly.
  9. McCombi

    40kw Boiler in 3 Bed Bungalow

    Unless I'm getting something wrong here with the figures, the gas rate for the figures you provided for one min of hot water use is very high. With using 0.188 as my difference between two readings over 2 mins i get this as a gas rate
  10. McCombi

    Boiler too high on wall?

    Would a hop up/platform not be suitable if only around 2m off ground?
  11. McCombi

    Diverter Valve

    If diverter faulty again I would have a punt at saying system water quality isn’t clean enough and causing to fail. Difficult to say for sure without seeing it. Not sure what boiler you have as lots o potterton combis but could also be plate heat exchanger is very dirty and gives similar...
  12. McCombi

    How to competely switch off DHW on Worcester Heatslave II oil

    I don’t think you will get hot water at all if you remove link though.
  13. McCombi

    How to competely switch off DHW on Worcester Heatslave II oil

    If there hasn’t been a twin channel programmer fitted then there will always be a signal to heat the tank I think. Without a twin Channel timer, there will be a link wire between mains live and (domestic hot water) dhw LR (live return) terminal. So basically always a demand to heat the store...
  14. McCombi

    Boiler installer not Gas registered

    We don’t have to notify boilers in Scotland. Doesn’t affect selling house etc like it can south of border
  15. McCombi

    Alpha C27 Combi Boiler over pressurises once or twice a day then vents

    You say rads are scorching hot, I noticed the thermostat in picture is half way, turn it lower and see if still scorching hot, I have a feeling it’s temperature related, ie overheating and not shutting off, but would expect overheat stat to kick in before this. Not familiar on them. Are you...
  16. McCombi

    Radiator Valve Reducers

    Probably sorted already but Screwfix dont do 8mm ones anymore and the Danfoss Trv packs that state 8 and 10mm included in catalogue don’t come with 8mm anymore either. I learned the hard way couple of months ago.
  17. McCombi

    Isar HE35 no CH after PCB replaced

    £600 quote to replace pcb. Was there anything else mentioned to be done for that price? Who quoted that if you don’t mind me asking? HE fault isn’t always pcb, can be a few things. LE can also be a few things. Can’t really give anymore help as checks would need to be done by someone...
  18. McCombi

    LPG Combi but not too pricey..

    A quick google search of lpg boiler Spain instantly picks this site up Much cheaper prices than you quoted, unless I’m missing something by not actually reading page
  19. McCombi

    Worcester 28i Junior issue pilot keeps going out

    Hi, it’s not a junior. It’s looks like a 28i rsf. Pcb common to fault and have got many going with a wee tap to housing. Best get someone in if you’re not competent to do safety.
  20. McCombi

    new boiler quote + optional extras

    do you currently have zone valves to independently have heating or hot water on by themselves and room thermostat at the moment? If not, it’s not really an option, you need these to bring system up to standards. As for price, can’t really comment without seeing the job, but remember it’s...