  1. McCombi

    ACS help compartment vetilation

    Was just jesting, although my memory seems to be deteriorating, keep forgetting things the missus tells me etc, thankfully I still remember the basics of gas safety.
  2. McCombi

    ACS help compartment vetilation

    A typo by the looks of it. The end result is correct.. Or is it. I'll report back after this White Russian
  3. McCombi

    British / Scottish Gas Engineers Please Read

    Bg/sg have their own in house procedures. Bare minimum checks that a gas safety check needs. From regulations 26/9. Fluing Ventilation Safety devices Gas rate/burner/inlet pressure Some engineers may go a bit further but that's up to them. As said, more of a safety check than a service...
  4. McCombi

    Alpha CB24 Boiler - Heating But No Hot Water

    New boiler for a diaphragm job. Madness!
  5. McCombi

    Plastic pipe identification

    Didnt think so pal.
  6. McCombi

    Plastic pipe identification

    I mean even when installing guidelines have been followed.
  7. McCombi

    Worcester 28CDi RSF - Replacing leaking hot water service connector

    Boiler doesnt need to come off wall. This can potentially damage flue As someone prev mentioned it can be done easier by removing whole hydraulic section. If you contact wb and explain the exact issue they will probably send the eng armed with whole hydraulics block. As it isnt vanstock item...
  8. McCombi

    Plastic pipe identification

    Yet to hear of a successful claim against a plastic pipe company anyway.
  9. McCombi

    Plastic pipe identification

    Came across the same stuff for the firat time a couple of weeks ago on a back boiler to sealed boiler conversion. Ended up ripping whole lot out and repiped as it was non barrier pipe anyway. Hep20 do adaptor fittings/inserts for them if you need them. As its same company now i assume they...
  10. McCombi

    Ridiculous costs for electrican's work?

    Can't see a qualified electrician fitting finished switches etc first. I wonder if they've been fitted by builders to try to save electrician costs and more money for builder.. bit skeptical me though
  11. McCombi

    boiler installation

    I saw an advert for this. Said you needed minimum of 3 engineers and 3 office staff. I would like to think if i had 6 staff working for my business, i would be in a good position not needing to adapt to a franchise.
  12. McCombi

    What's The Verdict On The Magnaclean Pro 2

    Pts usually have them in stock as bg use them. Not sure about other merchants, think I saw them in local Plumbase also but were more expensive there. Think Pts was about £80 plus vat but I have no terms with them. I still believe the mb3 doesn't catch nearly as much magnetite as adey ones...
  13. McCombi

    What's The Verdict On The Magnaclean Pro 2

    Fitted about 20, had one leak slightly at the push fit o ring bottom connection on the unit. Removed and had a look and there was a wee nick in the o ring, whether it was me or factory not sure but Pts replaced no problem.
  14. McCombi

    Gas Combi Heating Boiler ... 2 separate Timers ?

    As said combi boilers don't require a timer for hot water as they give hot water priority whenever tap run. Some for example Worcester boilers can still use a two channel clock but this is something for hot water preheat function, when a combi boiler is turned on, hot water is always available...
  15. McCombi

    Worcester 24i with megaflow Power issue

    Could be a greenstar 24i system. maybe there's no permanent live and it's wired via hot water switch live on programmer, ch zone valve may have been manually opened so radiators also get hot A competent rgi or sparky should be able to rewire for you.
  16. McCombi

    Potterton Prima 60F Boiler banging!

    Ive just seen you already have a thread relating to this problem from earlier in week. Did plumber not come back on Friday then? In other thread I picked up that a radiator is used as a bypass, is that correct? If the rad is after the zone valves then it won't work as bypass if valves...
  17. McCombi

    Potterton Prima 60F Boiler banging!

    The pump should run if pump over run thermostat senses 80degrees or more. May be worth checking that it is wired correctly though. In wiring centre inside boiler, below control kn Should have the pump connected to pump terminals A permanent live connected to L And switched lives from the...
  18. McCombi

    Potterton Prima 60F Boiler banging!

    Also worth noting that the pump is controlled by a pump over run thermostat in the boiler, it senses the temperature in the boiler, if system is still too hot and pump over run is on, turning off the programmer shouldn't turn pump off, it sounds like the boiler isn't wired correctly, and...
  19. McCombi

    Potterton Prima 60F Boiler banging!

    Plumber has maybe closed bypass when replacing the 2 2 port valves. If the pump is wired to the boiler and bouler set for fully pumped, the system needs a bypass before the 2 port valves, or the heat will have nowhere to go to when pump overrun is active after a boiler demand.
  20. McCombi

    Opinions on Boilermate BP?

    Plenty of the older ones still going strong up my way. Usually if I'm called to a repair it's normally failed pump or faulty mixer valve, the water is soft here too so Luckily don't encounter scale in dhw circuits. Not many of the more modern ones so can't comment on them.