  1. Blooflame

    help please

    Mate put some water ionto the system first... if your gauge ain't working, get it fixed...perhaps it isn't broke and you're not topping the system back up to 1.5 bar? when u bleed u must retop the system again...try that then let us know what the boiler does
  2. Blooflame

    Suprima boiler keep relighting

    As gordon says frost stat, ...if not your valve is sticking open
  3. Blooflame

    Overpumping question

    Or you could convert to a sealed system
  4. Blooflame

    Pumping over problem

    Blockage is usually where pipe B meets pipe C. Pipe A should not rise directly upwards from the vertical, rather should be from the horizontal after about 200mm (not usually practicable). As Gasman for 45yrs says, cut it all out. Use an airject.
  5. Blooflame

    Boiler problem

    If it lights for about 6 - 7 secs and cuts out the problem is rectification. Been to one the other day, cleaned the rectification post and it fired fine, never recalled to me. It was doing what your boiler was, sometimes ok, other times not. I would feel a lot better cleaning the post with some...
  6. Blooflame

    Pumping over problem

    blocked cold feed mate, the pipe from boiler must turn horizontal before the vent (22mm) rises followed by the cold feed (15mm) - use an airject would do the trick. If all those factors are observed then the cold feed is usually blocked
  7. Blooflame

    baxi solo 3 not lighting, what is sequence of operation?

    If you follow the flowchart to the letter, it will take you to the fault mate
  8. Blooflame

    baxi solo 3 not lighting, what is sequence of operation?

    you shouldnt get 0 ohms, you should have a readable resistance which will be the same as when the 2 leads are together (test). there will be OL not 0 ohms mate - that means it is screwed. link it out for test purposes
  9. Blooflame

    Using flue outlet for prv discharge?

    Never seen it and it is totally illegal...as you probably well know...how can the prv run into the air intake of a flue and be right!!? This must be a wind up mate
  10. Blooflame

    WHY ...Viessmann or the Remeha

    Whaaaa.....!!?
  11. Blooflame

    Vaillant ecoTEC plus 'Diverter Valve' leakage

    I just can't believe all this
  12. Blooflame

    Vaillant ecoTEC plus 'Diverter Valve' leakage

    WTF....Antifreeze?? Is this a windup mate. If u have indeed put antifreeze in the system.. I'm out of here b4 I make an extremely rude comment. That will almost certainly void your warranty.
  13. Blooflame

    Vaillant ecoTEC plus 'Diverter Valve' leakage

    I think u'd better start by returning those valves under warranty mate or ur gonna go broke. I've never heard of DV's packing up so quickly on these
  14. Blooflame

    HOT WATER PIPES GURGLING - AIR IN SYSTEM SOMEHOW??

    sludge will cause this, but more likely it'll be ur pump mate
  15. Blooflame

    same old question ? plastic or copper ?

    We have found that plastic pipes only accentuate the Electrolysis process and thus have been to properties only 8 months old with pure black system water. To add salt to the wound, it can't be reliably powerflushed
  16. Blooflame

    Vaillant Turbomax 24E combi boiler constant rising pressure

    The only thing it can be is the plate to plate, nowt else, otherwise we aren't getting the full info from you here. If the boiler is running then it will naturally rise in pressure. Are you saying that the pressure rises whilst the boiler is off?
  17. Blooflame

    Vaillant Turbomax 24E combi boiler constant rising pressure

    Actually I've had plenty of plate to plates passing ..it's more prevelent than you think
  18. Blooflame

    Alpha CD50s anyone got experience of it

    Why would you want to fit an Alpha?