    Boiler and immersion on same MCB?

    So I can assume cable calcs are being made based on 230v now? Used to be 240v and so would have been 12.5A.
  2. D

    Boiler and immersion on same MCB?

    I've had a rethink and will take the supply to the boiler in a spur from the downstairs ring and give the immersion it's own supply as recommended. I was only considering it as the boiler is below the HW cylinder and I was thinking of using the nearby socket for a spur to something else. I...
  3. D

    Shower pump supply

    I could pull it in to the ring but it would be a lot more work. I can access the conduit to a nearby socket from below if I take down a sheet of plasterboard. Is there any reason not to put 3x flat t&e 2.5's in 20mm plastic conduit apart from they won't fit easily? Thanks
  4. D

    Shower pump supply

    Thanks. That's what I was thinking. But hoped someone would say 'no problem' as I will have to try to get 3x 2.5's into 400mm of 20mm conduit or make holes to get into the upstairs ring.
  5. D

    Boiler and immersion on same MCB?

    Of course. Fused switched spur.
  6. D

    Boiler and immersion on same MCB?

    Is it bad practice for a 3A supply for a boiler and a 13A supply for a 3KW domestic immersion to be on the same RCD protected 16A MCB? If ok would it then be advisable to fit a 20A DP switch to the immersion so it could be fully insulated if a fault arose and then the boiler could still...
  7. D

    Shower pump supply

    Is it wrong to run a 2.5mm t&e spur off of the RCD protected downstairs ring to supply a shower pump on the first floor? It would be easier for me at this point but I'm not sure it would be 'good practice'. ie a circuit downstairs feeding something upstairs? Thanks.
  8. D

    A couple of questions.

    Deleted - Too many questions and too much info.