    new installation or addition

    if power to a shed is taken off a fused spur from a socket in a conservatory, to a cu in the shed,is this an addition to a circuit or a new circuit. and which paperwork would a spark issue, just a query from reading threads,
  2. P

    relocating controls

    thanks agile.what can't be controlled from the remote stat
  3. P

    testing and tails

    very helpful ebee, thanks
  4. P

    testing and tails

    thanks adam, very helpful,so how would you test that the bonding between the various items in the bathroom ie taps radiator towel rail etc is effective if the bonding was done in a cupboard next to the bathroom.
  5. P

    relocating controls

    i was'nt expecting humour from plumbers? can anyone give an answer who is not a comedian.
  6. P

    relocating controls

    anyone have an answer?
  7. P

    testing and tails

    anyone
  8. P

    relocating controls

    can the controls i:e timer settings/on off switching etc. be located away from the boiler into another room. it's a worcester junior 28i. is it just electronic cabling to be run or is there some 240 volt work.
  9. P

    testing and tails

    thank what if ,there is just the lights and an extractor (run off the light circuit) protected by a 6amp mcb. could you explain the procedure of how you actually test to check the bonding please.
  10. P

    testing and tails

    thanks adam,no i am not fitting one,when i read about something i like to understand it. wy is no one giving me an answer to the testing of bonding in a bathroom?
  11. P

    testing and tails

    thanks chivers, i understand the reason for the bonding,as my post asks,at what points do you measure to verify the bonding is doing what it is supposed too. and what size tails should be used for a separate shower 50 amp rcd.
  12. P

    testing and tails

    no one have the answers? or is there something wrong with the questions?
  13. P

    fault finding

    i have only two zones being used on my alarm,in the last three weeks it has been set off four times,twice in one day,when it is sounding the zone 2 led is flashing,zone 1 on constant. i have no pets. how do i go about finding the fault.i am pretty sure nothing moving in the house is triggering it
  14. P

    testing and tails

    i have been reading about bonding in bathrooms,and it mentioned testing with a low ohmmeter.but where do you test?is it just between the connection straps on the pipes,or is it at the taps,radiator etc.what reading is acceptable. also what size tails should be used when someone has fitted a...
  15. P

    boiler error code

    thanks agile. just depends,if it is fitting a replacement and testing system for a leak,i would do it myself.if it was more involved and needed some sort of setup,but someone would tell me,i would do it myself, but if it needs some equpment i hav'nt got i would have to get someone in.
  16. P

    boiler error code

    thanks for the quick replys. why do i need an engineer? which part is the problem
  17. P

    boiler error code

    i have a protherm 80, which shuts down and is intermittently showing an F1 error, it can be 3 or 4 days or twice in a day, it can happen either with the heating on or off. the book it says no flame detected. check flame sense electrode/ignition electrode. ignition unit on gas valve, fan and...
  18. P

    floor running down in toilet

    i have fitted a toilet where the back fits flush to the wall,but the floor of the toilet runs down,so the base of the pan is about 12mm off the floor at the front. amyone come up with a clever idea to support the front?,as it would need a wedge shape to support front to back.plus how to hide it.
  19. P

    incoming fuse rating?

    thanks to you both
  20. P

    incoming fuse rating?

    how do you find the incoming fuse rating(60/100 amp) if it is not shown on the cover.it still has it's seals in place.