  1. B

    British Gas domestic customers

    I screwed them for years and i'me still using their fittings 20 years on :lol:
  2. B

    Mains hot water pressure without a Combi or Unvented system

    what do you plan to use to heat your cylinder/s ?
  3. B

    Mains hot water pressure without a Combi or Unvented system

    Hi: What you want is available or you can knock up your own using an external heat exchanger,pump & flowswitch.Try these links. http://www.heatweb.com/pdf/DPS/White%20Box.pdf http://www.albionwaterheaters.com/pdfs/sales/mainsflow.pdf
  4. B

    Opening fireplace-Back Boiler??

    Taken out a few over the years and a lot of these were copper so at todays prices i will give you a tenner for it :wink:
  5. B

    Asymmetrical Olive

    The compression nut goes against the left hand side of that olive as you look at it in your pic.
  6. B

    Cup Joint?!!

    Used to do lots in days gone. Open the compo with a turnpin to make a bell shape.tin a piece of copper and tap into compo add flux then fill with stick solder. If you roughen the end of the copper before tapping into the lead it stays put while soldering.
  7. B

    Plate heat exchanger or internal coil

    As above.external exchanger with pump and flowswitch. google DPS Hi-Flow. I am about to do same.
  8. B

    heating system design

    Ignore the three posts above as it's obvious that they don't know what they are talking about and have never fitted a system boiler and you might not need an RGI....no one said gas. Put in two zone valves on the flow where you can and don't forget a bypass before the valves.It would be neater...
  9. B

    New central heating install - what to do!

    Go for a multi fuel boiler with a twin coil cylinder and hook up to solar or a heat pump. Check out mainsflow http://www.albionwaterheaters.com/pdfs/sales/mainsflow.pdf There are a few on fleabay. Insulate.insulate,insulate.
  10. B

    Need help! No hot water or heating after boiler man came :(

    Gas valve problem ? Fan and venturi problem ? Get the guy back as it's hard to say without being there.
  11. B

    How long to convert from conventional to combi CH system?

    Without new rads....one day But you might/would be best to rip it all out and go from new....3 days
  12. B

    the nige & tony show

    Have you seen them :?: The Gruesome Twosome :shock:
  13. B

    Telescopic P-Trap not long enough!

    There are 5 extensions on fleabay or Mcalpine T12A.
  14. B

    old steel water pipes / adding copper??

    I got my teeshirt before most of you and would use a 22mm compression fitting depending on what size iron pipe you have 8) Done a whole heating system in a church once using black iron...never again.
  15. B

    water tank over flowing

    Could be a split coil in the cylinder. When hot the coil expands,split opens up.
  16. B

    worcester 24i rsf-cant bleed

    The AAV is on the top of this boiler...as i remember ?
  17. B

    Flue for Little Wenlock Classic.

    MI's instructions are all you need to follow regarding the flue.
  18. B

    Biasi garda HE dead

    power supply, pcb fuse or pcb. There is a pcb for that boiler on fleabay item no 330522650863