  1. B

    Worcester 24i Combi - water too hot

    1ltr in 18 secs is carp and should be more like 2.5 ltrs on this boiler ?
  2. B

    Patching copper flushpipe

    MILLIPUT :shock: Solder it like a real plumber. Tin a piece of copper and fix it proper :wink:
  3. B

    Joining the BG Club

    I joined in the 80's,made my fortune and left 8) Lots of fiddles in them days :wink:
  4. B

    ONE RADIATOR DEAD COLD

    TRV pin jammed in ? Remove valve top and see if the pin is jammed in.
  5. B

    Bossing lead??

    OXYACETYLENE chris ? Oxypropane is what i use/used :wink:
  6. B

    Transition from Copper to Barrier pipe 15/15 & 22/22 (mm

    pushfit or Compression with insert. metal inserts are better with compression fittings.
  7. B

    gas fire installation

    If your existing fire is a Baxi with FOUR radiants then you may be in luck with changing it. THREE or FIVE radiants mean you are out of luck. Price would depend on your plumber/gas fitter as these fires are not cheap.
  8. B

    Hot water cylinder

    I don't use plastic but i am sure if you refer to manufacturers instructions it will tell you you can providing it is 1 metre from boiler i think ?
  9. B

    Hot water cylinder

    You can do either regarding capping or making a loop BUT make sure you leave a vent pipe and cold feed from tank in loft :shock:
  10. B

    My first soldered joints - how they look?

    Too much heat but not bad for first try 8)
  11. B

    Very Noisy Pipes

    This sometimes happens when a stop tap has been altered. Try turning the stop tap back half a turn at a time and see if the noise stops.
  12. B

    32mm Waste Pipe - Slight Misalignment

    fit one of these. Adjustable from o to 90%.
  13. B

    Looking for a guide to using push fit Polypipe

    Yer Tiz 8) http://www.johnguest.com/
  14. B

    HAS BAMBER GONE?

    Yes but he left me his tool kit :D
  15. B

    Glow Worm 30 Ci losing pressure, slowly

    It could be air in the system still from when he repaired. Why don't you shut the boiler off at the power and pressurise to 2bar for an hour or so :shock: You will soon find any leaks if you have any ?
  16. B

    Heating system...how to get it to work?

    Does it look like this :lol:
  17. B

    30 HXI F1 fault

    F1 fault would/could mean ignition lead or igniter defective,gas valve needs adjusting,lack of gas,air intake duct blockage or check connections on igniter.
  18. B

    Biasi 24 S and 24 SR

    I have all new spares for this boiler if needed :wink: :wink:
  19. B

    Biasi 24 S and 24 SR

    Biasi boiler manuals are excellent and the boilers themselves are the best £ for £ boiler on the market.....says i :shock: Grill.....a short pulse flashing light every 4 seconds means the boiler is in stand by condition. Very fast pulses (4 per second) means faulty boiler. As per a...
  20. B

    primatic cylinder

    Most plumbers don't put inhibiter in primatics or you will get a funny smell in the bath water,your testacles will shrink and your hair will fall out :shock: