  1. D

    3000V spikes, bad earth and burnt out A/C

    I work in an IT Department for a large call cente solutions provider in Leeds (Also in Dearne Valley too) We spend a lot of money on our infastructure.. APC Ups are ok for a small company.. but for the loading your talking about forget them. Its just not cost effective to have a ups per...
  2. D

    test equipment

    how do people get around the rcd tripping when testing..(ill wait before I say my method)
  3. D

    f-type plug

    www.maplin.co.uk
  4. D

    Part P and the death of home security...

    And get their hands out of neat consumer units :mad:
  5. D

    ECU TESTING

    I can test subaru ecu's for you :D
  6. D

    70 degrees or 90 degrees.

    Plugwash, I've had no probs.. even up to 35mm three core.. What do you use to strip it, a proper cutter for armoured cable or knife around and then cut away like peeling a potato, with the knife parallel to the armouring.. the inner can get tougher but varies with brand. Cable that has...
  7. D

    70 degrees or 90 degrees.

    does it say XLPE on the cable?
  8. D

    Cable, conduit, multi utilitiesTrench question.

    Agree with the above and that pool looks :D :D
  9. D

    Cable, conduit, multi utilitiesTrench question.

    I have.. its not that hard if you know how to dig a hole though :D You know what i mean by that.. IE Dig a hole and then dig into it..rather than trying to stab horizontally.. anyway... Mini diggers are hard too especially if you cant move left and right hands independantly. Had to...
  10. D

    SWA

    just could be a little neater, rather than trying to force it out, as it may need brass bushes in each.. IYSWIM? And it would also require a seperate earth /cpc running to the gland. David
  11. D

    Tingling feeling from woodworking machinery

    Why cant he fit a erm..a Lug (the bit that comes with the gland) To the gland then using a crimped lug run some 6mm earth cable and run that to the terminal on the machine?? Leaving the armour exposed and putting it into the terminal isnt acceptable. I would rather have a three way...
  12. D

    Cable, conduit, multi utilitiesTrench question.

    Check with the installer, but its more likely to be plastic coated copper.. Gas pipes that go through a wall have to be within another pipe AFAIK. I would have thought it would be more like MDPE water pipe than Copper?? What do I know though.. just dont want you to have to do it twice...
  13. D

    wire in wall

    you need a cable toner / tracer.. or make holes in the wall and get them back to patch up.
  14. D

    Service fuse

    unless.... http://news.bbc.co.uk/1/hi/england/staffordshire/3457965.stm
  15. D

    Cable, conduit, multi utilitiesTrench question.

    you cant run a plain old copper gas pipe in a trench.. But im sure you know this.. How wide is the trench?
  16. D

    SWA

    As Far as I know then Yes.. 25mm Round Conduit may be better than clipping it. David
  17. D

    RCD Hell

    Borrowed Neutral?
  18. D

    Suggestions on how to do something

    cheers, talked them out of it :D Breezer, I took one apart and it has a relay rated at 5A. and Im sure its more lilkely to use a transistor to switch this on. David
  19. D

    Service fuse

    switched mode power supplies are about the dirtiest thing to connect as far as the REC's are concerned. Commercial industries do care about the power factor / balancing of phases. We have two 11kv supplies.. cant see how a school manages with 300A Especially with Aircon units & plenty of...
  20. D

    Bonding again

    because you will die if you do. What fookin cable would help!! Bonding what? Bathroom, Kitchen, Main Equipotential bonding? Supply type? David