Search results

  1. 121164

    Urgent bathroom/shower help - any plumbers around ?

    try the mira flight, they come with or without feet plumb center or builder center
  2. 121164

    valliant boiler fault 28

    what modelis it f28 on the ecomax is no gas insufficient gas ignition lead defect
  3. 121164

    LapTop or PDA???

    lap top much better for zooming in on parts also had some dodgy dvd manuals. try www.themanualslibrary.co.uk its £25 a year but lots of old stuff as well.
  4. 121164

    broken two port motorised valve

    Is the valve broken or has the motor failed ?
  5. 121164

    Switchmaster

    The ACL Switchmaster 805 programmer is still available from hrpc part of the wolseley group although i think there is also a 601 you could try hrp xpress parts line 01772 819671
  6. 121164

    potterton profile 100e

    thanks chaps but flue is fine. there seems to be no air loss around the casing seals ect fans have been swapped and still get the same pressure differences? have put airline down heat exchanger and is working ok thanks for all your comments
  7. 121164

    boiler pressure problem, help!

    hi plumbgirl you will have to recherge the boiler it is basicaly a worcester you might have a white charging key that will fit into the right hand side bottom of the boiler or you will have a flexi hose to couple mains water and heatingretern connections see if you can locate either of...
  8. 121164

    potterton profile 100e

    thanks for the reply the air pressure switch opperates when you gently blow down red pipe on flue elbow and the boiler fires with the casing on i am only getting .35 mbr on the pressure switch on the same boiler next to it im getting 1.21 mbr have checked for blckages twisted hoses and...
  9. 121164

    potterton profile 100e

    can anyone tell me why my posts get canceled posted again lasted for 5 mins then dissapeared any suggestions potterton profile 100e not fireing air pressure switch and fan are fine just .35 mbr at pressure switch. no kinks in pipe work and flue is not blocked
Back