Search results

  1. A

    LABC boys love a shower.

    looks plastic.. ARCing!!! that sounds like fun.. so get the supplier to come round and fit an isolator.. do they do that? expensive? or if i feel ok about existing main fuse just shut down the CU and away i go?
  2. A

    LABC boys love a shower.

    ok thats great thanks. dont fancy removing tails without removing fuse first so will do it that way. why would i need to isolate the CU first. is it not isolated when i pull the main fuse. Also sm1thson what is a "metal cutout" you mentioned please? appreciate the feedback guys thanks.
  3. A

    LABC boys love a shower.

    will mr bco get the hump about the main fuse? "metal cut out"?
  4. A

    LABC boys love a shower.

    thanks BAS new you woul dget back to me..appreciate that. was just a little concerned re bonding sizes. but checked my red book and 4mm for sup and 10mm for main appears to be correct.. Isolation!... fuse fairy cut seal before i started.. apart from calling supplier cant see way round it..
  5. A

    A bit late, but...

    BAS i like that.. another one for my never ending list of resolutions. Being the fountain of knowledge you are any chance you can check out my latest thread please."LABC boys" your advice appreciated. thanks atm
  6. A

    LABC boys love a shower.

    Just putting in a new shower myself and have the LABC coming round for a cuppa before i go ahead. 8.5kw. NO room on the existing board. So going for dedicated mini shower cu with 40amp RCD and 40amp mcb. 100amp main fuse. i am coming from meter into Henley. then 25mm tails to existing CU...
  7. A

    just to keep BAS happy!

    thanks JohnD. new i was missing something. will sort sup bond sharpish. did everything else sound ok.. just wanted to get my facts straight before i get LABC round for a chat. and sorry there is an RCD for the sockets.
  8. A

    just to keep BAS happy!

    Just putting in a new shower myself. 8.5kw. NO RCD on the existing board and no space to put one. 100amp main fuse so putting in a Henley and Splitting tails (25mm) and installing dedicated mini Shower CU and renewing the cable to the shower with 10mm t&e is only 5m away. Gas is bonded but water...
  9. A

    shower change

    Just putting in a new shower myself. 8.5kw. NO RCD on the existing board and no space to put one. 100amp main fuse so putting in a Henley and Splitting tails (25mm) and installing dedicated mini Shower CU and renewing the cable to the shower with 10mm t&e is only 5m away. Gas is bonded but water...
  10. A

    Best Combi Drill

    no wrong does not have the lith bats.. mine arrived yesterday. http://www.toolstop.co.uk/bosch-gsb18ve2-li-turbo-tough-18v-li-ion-cordless-combi-drill-2-batteries-fleece-p6203 not form here though and you can keep the fleece.. got mine on the bay. paid 255 delivered brand new with...
  11. A

    Best Combi Drill

    more money than sense sorry......got it.... http://www.toolstop.co.uk/bosch-gsb18ve2-li-turbo-tough-18v-li-ion-cordless-combi-drill-2-batteries-fleece-p6203 paid £255 delivered..arriving this saturday... wo wo...
  12. A

    weight problem!!

    thanks Stivino but wrong model,, is not the turbo.... unless the spec is massivley different or axinster or tool stop are fibbing.. turbo is what i want.. anybody please???
  13. A

    weight problem!!

    neo,, look carefully.. those in that manual are old ni cad.. i had alreadly looked at that.. next?
  14. A

    weight problem!!

    this is what i think i want over the 36v combi however just wanted to check the weight of it.. does anyone have any idea please.. bosch site does not even have this model. many thanks...
  15. A

    Best Combi Drill

    Think this is the puppy.. problem is cannot find out how much it weighs.. any thoughts please... it is not even on the Bosch website. Bosch GSB18VE2-LI Turbo Tough 18V li-ion Cordless
  16. A

    big red book

    Gavin you legend!!!!!!!! don't feel like topping myself now ta. Anyone out there thats had a first visit from Napit? thanks
  17. A

    Best Combi Drill

    Hi. I currently own the Bosch 36v VF-LI Wot a bit of gear.. Got it for £400 delivered and never looked back since. One problem. Is big, heavy and not for every day use.. especially up a ladder. I really need the Bosch 36v VF-LI but on a samller scale. Will live without SDS but need...
  18. A

    big red book

    thanks scouse, i must sound like a d!ck. did have a job for a week with a firm however they went under recently and everyone in my yellow pages doesn't seem to be employing at the mo. I have past my EAL Domestic Installers course and reading my big red book everyday and have been trying to...
  19. A

    big red book

    thanks again mike... so when calcing the VD do i use the prospective draw of hot tub ie 24amps or the breaker amps ie 32amp?
  20. A

    big red book

    thanks mike. will use the clipped direct method to be on the safe side. as for the VD. i am hooking up a 5.5kw hot tub so it will draw 24amp. will be using 32amp breaker. cable length is 15m. iam meant to use 24amp (ie prospective current draw) in my calcs not beaker size correct...
Back