  1. T

    leak on the filling loop connector

    would be either flow/return and the cold feed ( the two iso valves that connect that pipe) they are not special no, one out of my aldi washer kit worked.
  2. T

    leak on the filling loop connector

    you wont need to drain anything, isolate both valves and replace.
  3. T

    Qvis

    what would you recommend for around £200? the swann cameras are much better than the qvis, its only for a small retail shop.
  4. T

    Qvis

    Yup, failed a long time ago by the looks of it. Replaced with swann. Cheers
  5. T

    Qvis

    I have a qvis cctv system at my business and just found out it doesn’t record. I have tried every menu but cannot figure it out. it used to record and when selected a date would show all green during the times but now nothing. can anyone help
  6. T

    Combi Boiler providing hot water but no heating?

    But the remote control thermostat should be providing the demand to the boiler. Have you changed the batteries ?
  7. T

    Combi Boiler providing hot water but no heating?

    How do you control your central heating ? It could be a dodgy room thermostat.
  8. T

    Combi shower going Hot-Cold-Hot problem

    the water ways are so small on a plate to plate heat exchanger that the water transfer when blocked isn't fast enough, this then causes the hot water temperature to rise quite drastically causing the burner to go off, then once it cools back down the burner lights up again. Well this is what I...
  9. T

    Combi shower going Hot-Cold-Hot problem

    It sounds like you have a block plate heat exchanger. Why was it replaced 3 years ago?
  10. T

    Valliant pressure vessels and F75

    When you drained down the system did you leave it opened ended when pumping the EV ? Most likely you have a fault pressure sensor as it should have showed 0 bar when drained down.
  11. T

    Vaillant central heating

    you need to balance your radiators by the sounds of it.
  12. T

    Vaillant - Water too hot.

    have you tested the thermistors ?
  13. T

    No pressure in heating system?

    bleeding your radiators will cause the pressure to drop.
  14. T

    Leaking tap

    Hi, Before I fix my leaking bathroom tap as it dribbles. Do I need to remove the cartridge to replace the washer ? or would it be best to replace the whole cartridge ( if so is there a standard size?) Thanks
  15. T

    washing machine

    Its on vinyl click, its a small kitchen and vibrates the sink toaster etc on the same side as the machine is, not built in
  16. T

    washing machine

    Hi, I'm looking for a new washing machine that doesnt heavily vibrate at the end cycle. I bought Hoover 9kg a couple weeks ago and it vibrated my whole kitchen, engineers been out saying its normal etc so I have the chance to replace it. I paid £269 for it but dont mind paying abit extra for...
  17. T

    Tamper on Pyronix outside bell

    Cheers appreciate it
  18. T

    Tamper on Pyronix outside bell

    Yeah that’s probably were I have went wrong, How can i deactive the bell when taking cover off?
  19. T

    Tamper on Pyronix outside bell

    Update - When taking the cover it, it does sound. But when I try pulling it the pivot seems to be already stuck in or doesnt move ( my brothers as soon as you pull it alarms) Now how do i sort this without the bell off?
  20. T

    Tamper on Pyronix outside bell

    Yeah I will do a few checks to rule out possible causes that you have mentioned, I actually bought the delta plus module due to the interal lighting it goes off during the night , so i rather have the tamper, Highly unlikely as its at the top of a two storey house, you need ladders but I think...