  1. B

    Worcester 18/25 combi hot water probs

    Well my customer phoned and told me the thermostat I fitted hasn’t cured the hot water problem. Seems he only gets a bowlful before the water goes cold, now I’m thinking flow switch anybody got any thoughts. Bob
  2. B

    Old oil (paraffin/kerosine) fired boiler problem

    I’d say you’re spot on John with all you’ve said if he gets the nozzle out he’ll find the size prob 0.65 let’s guess and say W so 110 will be the right pressure I make baffles all the time and have had no probs and,if it ain’t leaking I’m with you keep it. Bob
  3. B

    Oil burner locks out after running for a few minutes

    The capacitor is fixed to the motor. Bob
  4. B

    Rayburn 368k Boiler Lockout

    Have you got a manual it will tell you if not google it
  5. B

    Oil burner locks out after running for a few minutes

    There’s a thing called the three suspects coil, photo cell and capacitor.they can cause a heap of grief, I’d try the coil if it not that then you need to go into fault finding a bit more. Bob
  6. B

    Rayburn 368k Boiler Lockout

    I live on Lewis I’ve plenty of work look on eBay you may get spares and you can converse with the sellers. Bob
  7. B

    Rayburn 368k Boiler Lockout

    Just a thought is yours the vaporising boiler if so the coil may be a Parker coil and you may be better off getting the coil and valve complete. Bob
  8. B

    Rayburn 368k Boiler Lockout

    That is a really old boy you have there and I’ve not seen one for years,If I were you I would seriously be thinking of changing it.the guy who services it shouldn’t even be touching it we had one bloke on Lewis like that and he only cleaned the boilers,his repairs were a nightmare.With an old...
  9. B

    Rayburn 368k Boiler Lockout

    Not at all John I’ve always found you and terry to be gentlemen. Bob
  10. B

    Rayburn 368k Boiler Lockout

    Just ask for a BFP coil Danfoss is the make you need. Bob
  11. B

    Normal kero v. Glowmax.....oil men?

    I would touch it the only additive I use is Exocet. Bob
  12. B

    Rayburn 368k Boiler Lockout

    I think you’ll find it’s the coil on the fuel pump it’s the prime suspect when this happens. Bob
  13. B

    Trianco coal boiler

    Check all the moving parts and free them up may seem daft but coal works its way into every nook and cranny. Bob
  14. B

    Old Boiler Does It Need Replacing

    Ha ha god am I dim I looked at the title and thought it said oil boiler does it need replacing I’ll put my glasses on next time. Bob
  15. B

    Old Boiler Does It Need Replacing

    It’s an oil boiler. Bob
  16. B

    Worcester Heatslave oil boiler not trying to fire

    Didn’t think the Worcester’s have pump valves as the pumps one with bottom inlet side outlet. Bob
  17. B

    Private Sewage Pump Stations

    Ah yes it may be a Macerator makes sense if a single station. Bob
  18. B

    Private Sewage Pump Stations

    Yup bet it’s a flygt . Bob
  19. B

    Private Sewage Pump Stations

    I’ve worked on fen pumps which can shift 10 tons per second old Gwinnes pumps massive brutes. Bob