    Myson Midas boiler

    Fantastic boilers these! True fault finders dream.....or is that nightmare! What model do you have exactly as there is a bit of mist tonight and I cannot quiet see from here Stan
  2. P

    Yes, another Baxi Bahama problem needs sorting.!!

    You might want to get the syphon trap updated to the later one or better still pull the wire off it as I found a Baxi engineer had done on a job I visited :!: Stan
  3. P

    Help it's freezing !!! - Ignition (Spark) Generator failed??

    I would suggest that the main reason for the generator failing so often is that the spark wire has broken down and although the pilot and boiler continue to work fine the generator is continually sparking! The leads become high resistance due to break or more likely rust at the connection on...
  4. P

    Potterton Netaheat MkIIF 16-22

    My apologies too Chris. Again the mind is cloudy these days and the Netaheat badging never stuck that well. I seem to remember the MK1 and the electronic the most. So the MK11F had the white rodgers gas valve is that right? but still had the same ign box. Stan
  5. P

    Potterton Netaheat MkIIF 16-22

    Come on Chris! whats this are you having an off day? The pilot light is on and the fans running meaning that the boiler is still in demand. Plus its an F model which means its got the same sort of running sequence as the Profile. I would look at PCB or check for power to main gas solenoid...
  6. P

    Chaffoteaux Celtic FF. Pressure switch hunting.

    On the Chaff Celtic usually fan not running fast enough is a classic that is never found. Possibly venturi partially blocked. Its very rarly the switch itself but everybody always replaces it
  7. P

    Glow-worm Fuelsaver 35 F - pilot light keeps going out!

    When it goes out can you see a spark or hear it trying to relight?? or does it just stop demand and the fan stop. Stan
  8. P

    CCN1.....ACS...

    I always used to love asking engineers to explain the difference between Vapour pressure and a Liquid Expansion and how to identify each. Bring back Bi-mettalic strips that what I say. Serviced a Minerva the other day. Flippin great....took me 2 hrs almost. :) Stan
  9. P

    Vaillant VCW Combi problem and free beer

    Yep Chris is on the nail I would say. The impulse tubes tend to snap right where they enter the pump. You might be lucky if one of the pipes has come off! Stan
  10. P

    Boiler Cutting Out After Short Period

    Try checking the syncron motor in the mid position or zone valve depending on which you have. Stan
  11. P

    problem with my Potterton Profile 80e boiler

    If you have a white rogers gas valve then I agree as above but if the gas valve is a honeywell with 2 red solenoids I very much doubt it will be that. I would suspect the PCB as mentioned the dry joints are repairable (so ive heard) Stan
  12. P

    Vaillant VCW-Sine 18 T3WF H High Pressure Problem

    Its not. Unfortunatly what nobody has mentioned is that the expansion vessel is probably knackered and the diaphragm perforated. The OP could try it though. Agree with Tony lovely old boiler this. Fit a remote expansion and keep the thing running for another 10 years. It will probably out run...
  13. P

    apollo with too small pilot

    Quite right I always carry a top socket for these aswell. Usually shagged in 3-4 years Stan
  14. P

    apollo with too small pilot

    Get an engineer in who owns an injector cleaning pin. Common problem but is gas related so dont go trying to kill yourself :!: Stan
  15. P

    Nightmare

    About 45 miles away sorry. Dont think I could be competative at that distance. Besides got the inlaws here today and fully booked next week :? Stan
  16. P

    PLEASE HELP!!!!!

    Get a water softner for one! and then stop pouring money in to a pile of ****e and get a decent boiler for another Stan
  17. P

    Nightmare

    My advice would be to actually not pay whoever comes there and then but say that you will test the appliance for a few days and then make payment via post. I enjoy working on combi repairs and if I ever carry out a repair that I am not 100% will sort a problem then I actually will not take a...
  18. P

    Glow worm Comact 100e problem

    Could be the microswitch on the flow switch. Had many go wrong and its now been modified. Stan
  19. P

    How do I stick a toilet to a tiled floor?

    Cant you just put it back down with Red stuff :!: :lol: Stan
  20. P

    Cast Iron Rad Plug Removal (Tips Needed!)

    I remember having to get a bush out of a Mexico once or was it an e-type, anyways I used a hacksaw blade and cut out a section of the bush from the inside (yes be careful!) then caved it in using the stillys. Worked a treat and was the only way it was coming out. Stan