  1. P

    Repair or replace 13yr old poorly Worcester?

    If you have a 15 year old Worcester and you are thinking of replacing with an Ariston and off and on then dont! repair the Worcester. Stan
  2. P

    Repair or replace 13yr old poorly Worcester?

    If its yellow Chris it will be At Risk. ID is Red with BG Stan
  3. P

    Help Please C & M Britony safety valve

    Screw the nut on the bottom of the PRV in to lift it off the seat and depressurise the system then undo the bottom half using large flats on brass body. Clean the rubber seat and turn the washer over if nescessary then refit and tighten just over hand tight then undo the little brass nut again...
  4. P

    VCW Sine 18 T3

    Wax capsule in divertor valve is stuffed on far left. Remove lid from microswitch assy on top and see if flag moves with demand. If you select DHW preheat on front of control panel does boiler fire? Stan
  5. P

    Boiler Advice - Worcester Heatslave Junior

    Ahh a proper boiler. Stop before I get too excited :) I fancy driving all the way down there just to get my hands on it. Well done Namsag the power is strong with you my boy Stan
  6. P

    Boiler Advice - Worcester Heatslave Junior

    Are you sure Namsag. I thought these were the old floor mounted thorn M with a heat bank strapped on the side. Or is that the Senior. Ahh those were the days :wink: Stan
  7. P

    Types of CORGI ticket

    I only remember having to turn them upside down to get em working again when they stopped cooling :shock: Stan
  8. P

    Low inlet gas pressure - Worcester Greenstar 42CDI bolier

    I believe the words are Pressure Absorbtion or did it change :? If Transco test the working pressure at the ECV and its 19mbars then tough ti*ty Mr householder. Bear in mind Chris that a U6 will flow 6 metres cubed/hour. Even a 42kw Worc doesnt use that much gas so the drop across the meter...
  9. P

    Types of CORGI ticket

    Closed flue fires are Very interesting! Especially remember to turn them OFF before you spillage test! Oh yes :?
  10. P

    Types of CORGI ticket

    Ive got a question for you lads. When is a Residential Park Home not a Residential Park Home, but a Leisure Accomodation Vehicle and vice versa :lol: :lol: Stan
  11. P

    Dodgy Glowworm 30CXI.... help!!

    OP does the boiler stay in water demand. By this I mean does the front display show pressure and not temperature. Also if you put the boiler in DHW demand then remove the motor head from the divertor block on the left by taking the clip out does the rad still get warm and can you see the motor...
  12. P

    Types of CORGI ticket

    Just ordered two of the high speed versions(cant remember the model) but its 4.9kw which will dry a load in approx 30-40 mins apparently. Got one for me and one for another family member. Havent worked on one for years but have LAU1 anyway. They really are not that bad. They do a reverse...
  13. P

    Worcester 35 CDi pressure drop

    Had to replace a few Heat exchangers on these CDi's as they leak internally and the water disappears down the condensate drain. If you can try isolating the flow and return connections under the boiler (the 22mm pipes at either end) and then wait for a few days at least. You can still use the...
  14. P

    self cert

    Meeeeooooowwww, but I have to say I never looked at it from that angle. :shock: Stan
  15. P

    potterton netaheat 1016

    Also be aware that this boiler works on switching the NEUTRAL!! You might think you have a live coming out of everywhere but that doesnt mean the component has power to it. Poss seized fan BTW. Stan
  16. P

    myson appollo 80 boiler

    Or over heat stat.
  17. P

    Ravenheat 820

    On the front of the boiler next to the power switch Stan
  18. P

    Vaillant Ecotec pro 937

    I know but thats what they are saying. Will have another read on the website.They say it will do 200 l in 10 mins at 43 deg Does 15.2 l/min at 65 deg apparently. I think its because it works on the blending valve scenario. Like a thermal store I guess. Stan
  19. P

    Ravenheat 820

    No demand from clock or roomstat (if you have one) or you havent switched the winter/summer switch on the front :idea: Stan