  1. P

    MAIN MERSEY SUPER hot water gas heater

    If its anything like the Medway you probably find the pilots blocked. Failing that is it relativley new like 6 years because they have an overheat thermostat which interupts the pilot on the Medway. Not sure about the Mersey. Stan
  2. P

    Worcester-Bosch Condense Syphon Filling programme

    Yes it is ID. The condensate drain is classed as part of the flue so whoever left it in a bucket whats a kick! Luckily most boilers have an inbuilt siphon so you dont actually get fumes unless its empty! The Worcesters have a Syphon fill program which you can turn off if its peeing you off...
  3. P

    Changed DV on Ravenheat 820/20 problem with DHW

    You have a passing D/valve. Not unusual from BES from what I have heard and experienced. Stan
  4. P

    Combi recomendations

    I think you are crazy if you have a 24CDi to actually want to replace it with a cheap boiler! Sure they have issues like every other boiler on the market but get it fixed even in the unlikely event of the PCB being faulty. Stan
  5. P

    Worcester 240 ???????

    If its a grundfos pump I bet the impellor has come off the back of the pump. You have no circulation so if there is no blockage and you are sure there is no airlocks then it could well be that. If you turn on the boiler but leave the gas off then remove the screw from the middle of the pump...
  6. P

    Combi recomendations

    And how long have you had the one youve got now?? and how many times has it gone wrong? The only people who moan about their boiler are the ones who have a problem. You never get you mate in the pub say "You know what my Worcester boiler hasnt gone wrong in the last 5 years" will you...
  7. P

    fitting radiator in a loft

    Definatly not if you dont want the rad to heat when the hot water on
  8. P

    to slick922

    Can you spell aswell? Stan
  9. P

    no hot water on a worcester 24 cdi

    Very unlikely.Are you sure the pin is moving fully out!! Test microswitch with a meter before you buy one. More likely to be thermistor. Stan
  10. P

    TAKING FOREVER TO GET HOT WATER - HALSTEAD COMBI

    Divertor valve knackered, or certainly diaphragm anyway. P.S STOP SHOUTING ASWELL (Try hitting your CAPS key again) Stan
  11. P

    fitting radiator in a loft

    Also dont forget that the return from the rad has to go into the return before the DHW return ie.DHW last in otherwise the rads will again get warm when the hot water is heating only. Good this lark init :) Stan
  12. P

    Worcester 24i :(

    Just spray the old one with WD40 which will get it going until you can replace it. Stan
  13. P

    Faulty Worcester Juniour 28i Combi boiler

    I use parts centre and fitted one before christmas for a similar fault. Cost me £150 approx but that was with discount. Stan
  14. P

    Neataheat Profile 30

    Have you had any electrical work done recently?? Is the pilot lighting but no main gas or just not lighting pilot at all Stan
  15. P

    how to measure flame sense on ioinisation probe is working

    I would agree with that statement Paul until I went to service a Potterton Profile which at the time was probably 6 years old. Bearing in mind it was working when I arrived by the time I had serviced it it wasnt rectifying which I thought odd. Checked all connections and for continuity on the...
  16. P

    Boiler starts up when cold water tap turned off

    This is a work around and should not have to be done if the pipework both hot and cold is right without any deadlegs as mentioned. Either find the dead legs or fit an arrestor. Stan
  17. P

    how to measure flame sense on ioinisation probe is working

    Flame sensing works by passing a small AC Milliamp current down to spark probe which is then rectified by the flame when it lights which is in turn picked up either by the earth of the appliance or a n other probe as DC milliamps. Therefore who ever told you to test in series on milliamp scale...
  18. P

    worcester 28cdi rsf combi,no hot water

    Are you sure the pin is moving out of the divertor valve when you open the hot water tap :!: :?: :!: Stan
  19. P

    New wireless thermostat recommendations?

    Hence the original answer of yes a wireless will be a good idea and then put a trv on that room rad. Job sorted. Stan
  20. P

    Banging when zone valves close

    The direction of the head against the body is erelevant. What you should have done was pay attention to the direction arrow which of course the instructions will tell you :?: However lesson learnt I guess. The head can be rotated to any position within the constraints of the 4 securing...