    Pressure build up in Sime Super 90 mkII combi boiler

    The pressure relief valve will often leak after opening, due to debris on the valve seat. You could try operating it again and it may seat if you're lucky..otherwise would need replacing.
  2. H

    Is my next door neighbors boiler flue too close

    Taken from a previous tech bulletin TB150 issued by corgi: British Standard (BS) 5440-1: 2000 - Installation and maintenance of flues and ventilation for gas appliances of rated input not exceeding 70kW net (1st, 2nd and 3rd family gases) – Part 1: Specification for the installation and...
  3. H

    Word Association

    robert then
  4. H

    Word Association

    ford
  5. H

    ravenheat boiler flue distance

    In all cases the manufacturer instructions take precedence, if the installation complies with these then all good. For additional peace of mind you could install a carbon monoxide alarm in the room with the window, as per the manufacturer instructions. If the installation does not comply with...
  6. H

    ravenheat boiler flue distance

    Plume kit cannot fit vertical flue, which model ravenheat do you have?
  7. H

    ravenheat boiler flue distance

    Upon further research it seems the requirement is 2000mm, the 3oomm dimension is for wall terminations which of course fan the products away from the window. In all cases follow the manufacturer advice!
  8. H

    ravenheat boiler flue distance

    Hopefully you will be in possession of the documentation for your boiler, this will detail the distance required from an opening window. The dimension stated in the relevant british standard is 300mm as you indicate.
  9. H

    Boiler installation regualations

    As per the british standard , a flue termination must be more than 600mm from a boundary. If less than this I think your neighbour has a valid grievance. I suspect any non conformity would cause problems with property sales and the H.I.P.
  10. H

    boiler shutting off

    Is the hot water ok at the hand basin/ kitchen sink? Is the flow very much better from the cold than the hot water?
  11. H

    gas pipe in a stud wall?

    Ignore regs at your peril. As it happens the jury is still out on gas pipes under floors in new build with chipboard flooring, be a brave man who would take a gamble. As for spouting regs, they are what keep the industry safe I would hope.
  12. H

    gas pipe in a stud wall?

    The powers that be consider that t&g floorboards offer sufficient adventitious ventilation to disperse a gas escape should one occur, you can only work to guidance offered by those in the know. As regards installations in new builds with studded walls then guidance is readily available.
  13. H

    gas pipe in a stud wall?

    The ventilation requirements will no doubt be defined somewhere so I guess could be complicated to work out by the book.... :wink:
  14. H

    gas pipe in a stud wall?

    The gas pipe should be enclosed by timber battens sealed to prevent a gas escape from dispersing behind the plasterboard, either that or ventilate the void at high and low level. Looks a bit late in the day now thuogh... :?
  15. H

    gas pipe in a stud wall?

    Should the gas pipe have studding/ sealant either side of it behind the plasterboard to isolate it from the rest of the void?
  16. H

    Are room Thermostats mandatory?

    The building regs currently require one to be fitted, to prevent the boiler from firing when there is no real demand. Stops the boiler cycling?
  17. H

    !! Worcester 24i junior fitted, instead of 28i junior ? !!

    I'd second that, hold a significant retainer from him pending satisfactory performance. If you are ultimately happy then negotiate a lower price to reflect lower spec boiler.
  18. H

    Alpha CB24 Combo Boiler Pressure Problem

    Check to see if water is coming out of the release pipe ( outside the property) when you put the heating on, are you topping the pressure ie filling the system up? If so then likely to be expansion vessel charge or needs replacing.
  19. H

    Halstead Buckingham 4 not lighting

    Id suspect gas valve (solenoid jammed), check for 240v on connections.