  1. fazedup71

    Ideal Logic Plus

    I fitted the 24kw today, the customer supplied the boiler and it did appear to be good, but would I supply one myself? NO WAY It was nice to have the experience of fitting one but the way they have treated customers in the past is terrible, I have had the phone put down on me, been spoken to...
  2. fazedup71

    Cold tap turned off triggers boiler - new bathroom fitted,

    it's called bounce back, normally you will find that a section of pipe has been left in but capped off, I would speak to the plumber see if any dead legs of pipe have been left in, it is not serious but it is not desirable. I also agree that if there are no dead legs that a check valve will...
  3. fazedup71

    baxi 105e

    whats wrong with it? if it is blocked, have you considered cleaning it?
  4. fazedup71

    Boiler Madness

    am saying that a combi requires a cleaner system than an open vented boiler because of the plate to plate, looks like we both agree on the same thing, maybe i didn't put it very clearly. :oops: :oops:
  5. fazedup71

    Boiler Madness

    I completely disagree with the last part of your statement, modern combi's require the system to be a lot cleaner than say an open vented boiler does, whilst you would need to powerflush for either, the combi will always be more susceptible to damage from a dirty system
  6. fazedup71

    Boiler Madness

    well, combi's are ok but when they break down you tend to lose everything, they require a really clean heating system, however you do mention an electric shower, that is always a good idea to have one Personally am not a massive combi fan, you will probably need a lot bigger gas pipe, combi's...
  7. fazedup71

    ideal w2000

    what is the problem you are having with the boiler? are you gas safe? Just I notice you have asked a few questions about other boilers in the past. :?:
  8. fazedup71

    general question about g3 certification

    belive so, I got one when I did mine but it doesn't show on my gas safe card! I best be looking into why that is! :wink:
  9. fazedup71

    Working on boilers

    my own personal opinion is you shouldn't touch boilers full stop unless your a RGI, sometimes when I have a boiler cover off I see things, the signs that things are not right. You can certainly work on it if your not touching anything gas related but sometimes it is not so clear cut, take...
  10. fazedup71

    worcester r30 he combi plus hot water problem

    blocked Plate to Plate heat ex a big possibility, would certainly take it out for a look, bet it is jammed solid :D
  11. fazedup71

    Saunier duval 30e

    maybe you should have replaced the diaphragm :D :D
  12. fazedup71

    Saunier Duval F24 therma classic

    I would suspect the plate to plate heat exch is dirty, no need to get a new boiler
  13. fazedup71

    Could a faulty regulator affect the meter reading

    the regulator is before the meter, you have to appreciate that to get a gas bill 5 times the norm would mean a massive leak on your side of the meter, we are talking the kind of leak that causes explosions It has been a cold winter!! how much was your gas bill?
  14. fazedup71

    baxi 105he

    because you diverter valve might be broken
  15. fazedup71

    baxi 105he

    I am thinking Yoda is in the house!
  16. fazedup71

    Gloworm 30CXi leaking

    sounds like the RPZ valve, really common for these to go, also a good idea while you have it apart to check the filling loop, it's the blue tap plastic thing, both are prone to failure but are relatively cheap to replace
  17. fazedup71

    Gloworm 30CXi leaking

    no need to turn the gas off, however please do make sure to turn the power of to the boiler :D
  18. fazedup71

    Ravenheat RSF 820/20 boiler - diverter valve

    yes they are for isolating the boiler but they normally leak if you operate them. Sounds like the diaphragm has gone
  19. fazedup71

    Ravenheat RSF 820/20 boiler - diverter valve

    i wouldn't touch any of the isolation valves on the boiler, you might end up with leak city! does the boiler work when you turn a tap on? if it does then it might be the shower valve that is the problem, it also sounds like you have not isolated the cold inlet
  20. fazedup71

    Leak in Combi CH

    if it keeps going above 3 bar then yes!