    BAXI 105e wont stop heating radiators!

    right, i assume that the terminals 1 & 2 are the loop from the room thermostat??? removed these, and still the same problem. ( also replaced the thermostat as i hated the one i bought last year, and still same problems ) looking inside i notice the pin goes up, and turns the microswitch on as...
  2. S

    BAXI 105e wont stop heating radiators!

    lol, bloody combi boilers, nothing but headaches :D
  3. S

    BAXI 105e wont stop heating radiators!

    ok, now its stuck on constantly again :s
  4. S

    BAXI 105e wont stop heating radiators!

    well, i was going to try all of the above... but then tody it stopped being on constantly, and now it heats up, when it reaches the right temp, the boiler keeps "clicking" like its about to heat up, the green rad light comes on, the pump starts , then the green light goes out, and it all...
  5. S

    Day / Night room thermostat

    Im trying ( and failing ) to find a thermostat that can be used on a cmobi boiler that allows you to choose different temps at different times ( mainly cooler at night when i sleep, and warmer during the day ) Any suggestions on models etc?
  6. S

    BAXI 105e wont stop heating radiators!

    hopefully someone can help me! i have a baxi 105e combi boiler. the hot water works fine, but the central heating constantly heats the rads! the thermostat "clicks" when it reaches the right temp, but the hot water keeps on pumping around the rads! the thermostat battery went dead...
  7. S

    baxi combi 105e flashing light ( sensor fault light 11 )

    hi there thanks for the reply you wouldnt be able to point me in the direction for the manual that shows how to do this repair would you?
  8. S

    baxi combi 105e flashing light ( sensor fault light 11 )

    Hi there i have just moved into a flat with the baxi 105e combi boiler. The sensor fault light flashes after a while, the boiler starts to heat up, but then switches off again, it does that a few times then some times starts up. the rads still get hot, but not a constant heat. does this mean...
  9. S

    valiant Turbomax Combi , Flow Divide Valve problem?

    Having just moved into a flat, and the boiler needing a new pump, i thought my boiler problems were over with, but no! up until last week , when the hot water tap was turned on, the boiler kicked in and heated up the water. now it only does this sometimes. 50% of the time the valve...
  10. S

    valiant combi Bangs then died

    ok, ill do that!! thank you
  11. S

    valiant combi Bangs then died

    oh, and would this cause the fuse to blow?
  12. S

    valiant combi Bangs then died

    ahhh yes, that looks very much like what is on top of the pump!! i assume i tighten the black part on this!! would i need to get any air out of it anyway , or do i assume from the "auto air vent" i tighten this and then cross my fingers? :P
  13. S

    valiant combi Bangs then died

    im not sure, being a fick newbie to boilers, what would this auto air vent look like? my friend who diagnosed the fuse said there is possibly a air vent on top of the pump, guess this may need a twist!!
  14. S

    valiant combi Bangs then died

    the pressure is about 1.5 bar not sure if the fan is running, but the banging ( and gurgling ) sound starts when the pump starts to kick in, this happens for a few seconds, then all of the lights go out, apart from the 0/I power light , and it just "sits there" a few mins later is tries again...
  15. S

    valiant combi Bangs then died

    Hello all I have just moved into my first flat, as it is freezing first thing i done was turn on the heating, this fired up ok, and heated the radiators. about 15 mins later they all went cold and the boiler was totaly dead! the internal fuse in the pcb had blown, this was replaced and the...