  1. bazdaman

    BIG Scale problem?

    I would be changing the flex first, can we see a pic? Like you say it might not be passing enough water if kinked
  2. bazdaman

    leaking pushfit fitting

    **** on the seal face and or seal dried out take it apart clean it up and apply a little grease
  3. bazdaman

    Gas-Torch recommendation(s)

    TBH i dont think you need extra nozzles or remote head, i have never needed them for any job, if you improve your torch skills you can do it all with a sure fire 2
  4. bazdaman

    Gas-Torch recommendation(s)

    http://www.screwfix.com/p/rothenberger-super-fire-torch-propane-gas-cylinder/83005?kpid=83005&cm_mmc=Google-_-Product%20Listing%20Ads-_-Sales%20Tracking-_-sales%20tracking%20url&cm_mmc=Google-_-Shopping%20-%20Tools-_-Shopping%20-%20Tools&gclid=CjwKEAjw55K4BRC53L6x9pyDzl4SJAD_21V11WzfJ0atltTf3qrRu...
  5. bazdaman

    Vaillant Ecotec Pro 28 Water only Lukewarm, HELP!

    You get what you pay for... Or dont
  6. bazdaman

    Vaillant Ecotec Pro 28 Water only Lukewarm, HELP!

    The goverment grant boilers came with 2 years Min AFAIK, dosnt matter what the warranty card says in the boiler box everyone gets different.
  7. bazdaman

    WB Greenstar CDi

    If you take the heat ex front plate of you can sometimes see it spraying out or make sure boiler is stone cold then dry sump internally and pressurise to 2.5 bar if sump gets wet its the heat ex knackered
  8. bazdaman

    water left in pipes after pressure testing

    Not really, if the pipework is nowhere near full then there is plenty of room for expansion
  9. bazdaman

    Geocaching

    Its a great hobby to get the family out instead of staying in with internet and tv! Although i must admit i prefer to leave them at home and go caching on my own or with the dog!
  10. bazdaman

    "Piggy back" an existing rad

    What size pipe is at the hallway rad? If its 10 mm then i certainly would NOT tee into it
  11. bazdaman

    Remove kitchen tap with rigid copper tail

    I use a 1/2 inch male iron to copper for the flex to screw onto perfect fit.
  12. bazdaman

    Bi - diretional or nt

    Yes if you look at the pic it has bi directional arrows on the valve body
  13. bazdaman

    Too hot!

    Old systems were piped this way so its ok, unless you have a combi!
  14. bazdaman

    Baxi BB 401

    I wouldnt even of thought it was a boiler problem myself, Leaving a stat phail isnt really a boiler fault is it Tony thats just carelessness
  15. bazdaman

    soldering an air separator into central heating

    It should be your first step!
  16. bazdaman

    Baxi Genesis 80 not firing

    Tony is in the uk top 100 engineers you know :rolleyes:
  17. bazdaman

    Baxi Genesis 80 not firing

    Yes you are correct in what you are saying, i hope your linking harness end and not the switch! (Obvious i know but nothing suprises me) use a multimeter on continuity on the switch themselves when unplugged aswell just to check if not jammed.
  18. bazdaman

    Baxi Genesis 80 not firing

    Just the two flow switches one for a dhw demand the other to prove pump is running, thought you had a Ready tested this and its ok?
  19. bazdaman

    Baxi Genesis 80 not firing

    Have the new pcbs been set up correctly? There are lots of dip switches on the pcbs and links.
  20. bazdaman

    Baxi Genesis 80 not firing

    Link the ch flow switch out it also acts as a primary flow switch dont test anything inside the combustion box, the part tony refers to that can be cleaned out sound like the flow switch i mentioned, if that dosnt make when pump runs then nothing else will work