  1. I

    Boiler in a bathroom cupboard

    As its in a cupboard its not in a zone....... (example: Tested a property were the fuseboard was in the bathroom, as it was in a cupboard it was not classed as being a zone, I am still not convinced but I dont make the rules) Any other sparks comments welcome.....
  2. I

    Part p query

    A Periodic Inspection & Test could be carried out at the end, although would be or should be unsatisfactory due to an Installation Certificate not being available......if your post was meaning would a spark issue an installation certificate for you for a cash sum.....well it would have to be big...
  3. I

    extractor fan on lighting ring.

    Its fine..Usually there may be some sort of isolation (fused connection unit)
  4. I

    Sparky with part p prob

    ERRR.....Just because its an extension to a kitchen does not mean it has to be a kitchen.......
  5. I

    Sparky with part p prob

    Could you not wire the sockets from the existing downstairs ringmain as this would not be considered as new install work / works with a kitchen and should not require the approval from your local authority.
  6. I

    Type B RCBO's.

    Didn't think they were...
  7. I

    Help identifying MCB (*Pics Added*)

    The newer range of MCB will fit the old board... I got a 40A MCB (New) & 32A RCBO (Old) which your welcome to have.
  8. I

    2381?

    What scares me is 1986...... "Ian finally realises that he is overweight, losing his hair and now feeling old" Could be worse, I could be Jim's age :D
  9. I

    Oven and hob connections

    Personally, I would install a twin socket below your worktop in a cupboard and simply plug both appliances in.
  10. I

    Electric problem

    You mentioned junction boxes ? Where are these.....
  11. I

    Whats the standard procedure?

    Thinking of your own future ban.....
  12. I

    minor works cert

    As long you have covered yourself on the certificate by listing the defects that require attention.
  13. I

    Baby belling trips my RCD unit when cooking sunday lunch

    I am an Electrician aswell..... I concur with him above
  14. I

    Tingling feeling from woodworking machinery

    1)Sticker is required for guidence only as two sets of colours have been used from two version of the wiring regulations. 2)Not recommended, but common in older installations. 3)Only for a laugh 4)Because of the plastic accessories a seperate CPC (earth) is required, but the armouring...
  15. I

    Overpriced ?

    After the electrician has carried out the test, make sure you get an Electrical Installation Certificate :wink:
  16. I

    minor works cert

    Not too bad mate..... And yourself ?
  17. I

    flashing led's

    The problem I find with dummy cameras, is they do really look fake....but I suppose you need to try it first....the good thing about dummy cameras is that it wont record you giving the little s**t a strict telling off :wink:
  18. I

    flashing led's

    s*d the cameras.....buy a baseball bat.....
  19. I

    minor works cert

    just.....
  20. I

    minor works cert

    You have to put your details down. BS:3871 Type 1/2/3/4 BS:EN 60898 Type B/C/D Any departures affecting the circuit / board you have worked on should be noted. Any works that need doing should be made clear to the person ordering the works, any remedial works that affect the circuit...