  1. F

    vokera linea 24 has no central heating

    when u link out ta and ta does the boiler fire?
  2. F

    Alpha 240XP hot water issue

    Check the operation ofn the pin that makes the microswitch for your hot water, and make sure the hot water diaphragm is intact.
  3. F

    Vokera Compact 24 failing to ignite

    Never change the aps on vokera, ive been working on compacts/linea for 2 years now changed one aps in that space of time, never changed overheat stat.
  4. F

    LPG Supply

    Sure i like daggs, i like caravans more.
  5. F

    Biasi 24s, problem with dhw firing on and off when in use

    It's amazing how gas engineers argue with each other constant on this forum :)
  6. F

    vokera compact 28

    On the linea HE range its in the exact same positioning named as " drain valve ", why the compact hasn't this component named the same i don't know, but without arguing to me its a drain valve, and since using it i haven't had any problems with it leaking in any such way.
  7. F

    vokera compact 28

    The company i work with sub contract vokera we never drain from prv if necessary reagrdless of what anyone says end of.
  8. F

    vokera compact 28

    kevplumb, i work on a lot of vokera boilers the safety valve is a safety device and yes a drain valve, but i can almost guarantee you if you touch that safety valve it will not reseat and will partially pass water. So you turn up at a job to say fit a ntc heating sensor, the customer has...
  9. F

    Potterton Puma80

    THOUSANDS
  10. F

    vokera compact 28

    lol, its about an inch horizontally right of the prv, and the prv is not a drain valve its a safety device...
  11. F

    vokera compact 28

    Make sure you aren't mistaken that the leak is just running or dripping onto this plastic pipe, never have i seen the drain valve leak on its own.
  12. F

    Potterton Puma80

    Changed hundreds of these always burns top left corner, i've seen a whole board melted must have caught fire.
  13. F

    Radiator problem

    What is the sizing of pipe feeding the rads?
  14. F

    condensing mode

    To be honest most condensing boilers are a waste of money in my opinion, for the fact that a boiler will only condense under certain circumstances. On SE boilers the heat leaving the flue is somewhere around 170 or 180 degrees, condensing boilers being different, rather than letting the heat...
  15. F

    linea vokera boiler problems

    What you have wrote they're sounds correct the heating comes on, cuts off due to reaching temperature, the " blue light " goes off. The green light indicates power to boiler. What is the problem does it not come back on?
  16. F

    Hot water tap on, but no hot water, however CH comes on!?

    Possible problem with your 3 way valve cartridge, bobbin more than likely swollen or bent, passing hot water through your heating side partially.
  17. F

    Fitting smaller rad - extending pipes?

    Assured heating, i ASSURE YOU this is not stupid advice, but feel free to leave your opinion on why this may not be considered advisable.
  18. F

    Vokera Compact 24 failing to ignite

    The dhw sensor shows an amber light when faulty or when its on its way out. The primary sensor shows a red light. For a standard efficiency compact boiler this seems to be a constant problem. Unfortunatly a red light can be a mean a lot of differant faults on this boiler, as it does not give...
  19. F

    Ariston eurocombi mffi a23, CH on all time

    dommo slow it down for us please, take a step back. We haven't got any further thus far. As best you can describe the fault from a fresh. Forget what you have already written take time on this next post. The better you describe the fault the easier it is for people to understand whats...
  20. F

    Ariston eurocombi mffi a23, CH on all time

    How many is that now ? :P