  1. F

    Vokera Compact 24 failing to ignite

    Is it a flashing red light or a solid red light? Does this happen more in the morning than night?
  2. F

    Cistern won't stop filling...

    couldn't agree anymore, better purchase on tightening as well.
  3. F

    Protherm 80e boiler problem

    I am guessing you have an ariston eurocombi? what is the make and model of the boiler pelase.
  4. F

    Fitting smaller rad - extending pipes?

    Why not get a 700 rad, they will be available at most plumbing merchants and elbow one of pipes under the radiator so its not visible rather than having a horrible extension visible?
  5. F

    pressurisation ofCombination boiler

    vokera linea models have a lot of different reasons for pressure problems, so i will do my best to describe a couple of things you can check. 1. Top the pressure up to 1 bar exactly, that way your eye wont fool you, if you are persistently checking the pressure to see for signs of movement...
  6. F

    Explosive Ignition

    . poolebybirth, are you asking this question because you are concerned with your own or someone elses appliance? If so what is the make and model of the appliance.
  7. F

    Ariston eurocombi mffi a23, CH on all time

    Yes measure the "resistance". Aren't you going to advise dommo what the resistance should be, at certain temperatures the boiler reaches, to let him know if he is receiving correct readings?
  8. F

    Potterton Profile 80el fires up intermittently.

    Sounds like the gas valve is either not lifting because the pcb is dropping the voltage to it, or the gas valve is sticky itself. They're are a lot of different problems that can make this fault occur though. Have a competent gas registered engineer look at it.
  9. F

    How to drain my sime friendly format 80e

    The valve kevplumb mentioned is usually situated outside the house coming out of the wall around a foot up from the ground.
  10. F

    Ariston eurocombi mffi a23, CH on all time

    On this boiler they're is a main sensor, which i know on other models, can slip the boiler into frost mode, causing the heating to come on and off as it pleases, without a demand. Sensor's are usually very cheap and easy to replace. May not be the same case here as i said on "other models"...
  11. F

    Cistern won't stop filling...

    I dont rate torbeck valves cheap plastic. Anyway here is a link that might help you understand the operation of the valve a bit better. http://www.letsfixit.co.uk/html/cistern_hints.html
  12. F

    Ariston Microgenius II 27 - Error 33/34

    Unsure of the exact problem, but they're is a good chance of a partially blocked venturi, which can cause intermittent signals going to the air pressure switch. Mentioning to the engineer of a possible blocked venturi will more than likely direct him to the area of fault. The best way to clean...
  13. F

    halstead ace water dripping from group set by dhw switch

    They are usually referred to as pin seals, usually not listed with part numbers in manufacturers instructions. It would be better if you had the make and model of your boiler, preferably with the gc number. Then phone the manufacturers spares line to identify the part number. DO NOT tighten...
  14. F

    Vokera Mynute 20SE

    Craig, does the pin on the pump proving switch sit pushed fully against the microswitch when boiler is off/on?, cause as far as im aware, the pin has to retract back into its housing to let the microswitch lever away from the switch. If this doesn't happen when pump is running, you could have a...